Electrical Requirements; Electrical Connection - Jenn-Air JJW3830IM Instructions D'installation

Masquer les pouces Voir aussi pour JJW3830IM:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Electrical Requirements

If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and the wire gauge are in accordance with local
codes.
Check with a qualified electrical installer if you are not sure the
oven is properly grounded.
This oven must be connected to a grounded metal, permanent
wiring system.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition or CSA Standards C22. 1-94, Canadian
Electrical Code, Part 1 and C22.2 No.
O-M91-latest edition, and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575

Electrical Connection

To properly install your oven, you must determine the type
of electrical connection you will be using and follow the
instructions provided for it here.
Oven must be connected to the proper electrical voltage and
frequency as specified on the model/serial/rating plate. The
model/serial/rating plate is located under the control panel
on single ovens and under the control panel on the upper
oven cavity on double ovens. See the following illustrations.
A
Single Oven
A. Model/serial/rating plate
A
Double Oven
A. Model/serial/rating plate
Models rated from 7.3 to 9.6 kW at 240 V (5.4 to 7.4 kW
at 208 V) require a separate 40 A circuit. Models rated at
4.8 kW and below at 240 V (3.6 kW and below at 208 V)
require a separate 20 A circuit.
A circuit breaker is recommended.
Connect directly to the circuit breaker box (or fused
disconnect) through flexible, armored, or nonmetallic
sheathed, copper cable (with grounding wire). See
"Make Electrical Connection" section.
Flexible conduit from the oven should be connected directly
to the junction box.
Fuse both sides of the line.
Do not cut the conduit. The length of conduit provided
is for serviceability of the oven.
A UL listed or CSA approved conduit connector
must be provided.
If the house has aluminum wiring, follow the procedure
below:
Connect the aluminum wiring using special connectors
and/or tools designed and UL listed for joining copper to
aluminum.
Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
For power requirements for models JJW3430I and JJW3830I,
refer to the following table.
Model
JJW3430I
JJW3830I
240 VAC
208 VAC
kW
kW
4.5
3.4
9.2
6.9
5

Publicité

Table des Matières
loading

Table des Matières