2.3. On/off control
On/off control can be made via separate control for individual units (refer to Fig 1-3), or via
single control as shown in Fig 2-3.
FPS1000 #1
FPS1000 #2
FPS1000 #N
3. SERIES OPARATION
Up to 3 units can be used for increased output voltage
It is recommended that diodes be connected in parallel with each unit output to prevent revese
voltage. Each diode should be rated to at least the power supply rated output voltage and
output current.
Series operation is not applicable for units with I
FPS1000
FPS1000 #2
7
ON/OFF
10
SIG.
RETURN
7
ON/OFF
10
SIG.
RETURN
7
ON/OFF
10
SIG.
RETURN
CAUTION
+S
#1
+V
-V
SIG.
ON/
-S
RTN
OFF
10
7
+S
+V
-V
SIG.
ON/
-S
RTN
OFF
10
7
(*) Diodes are user supplied