Description; Operation - Dustcontrol DC AirCube X2 Notice Originale

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Description

The DC AirCube X 2 Air Cleaner is intended for
cleaning the air in a work area and is intended for
u s e a s a c ompl i m e nt t o s p ot e x t r a c t ion . T he
DC AirCube X2 consists of two complete units on a com-
mon chassis. Each unit has got two fi lters and a fan. Air is
passed through a combination fi lter and a HEPA fi lter. Th e
HEPA fi lter actually separates particles to 99.97 % (DOP).
Th e combination fi lter separates the majority of the particles
and thereby
prolongs the life of the HEPA fi lter.
When a loss of suction capacity is experienced the

Operation

Connect the machine to a suitable power source according to
the specifi cation of the machine. When using an extension
cable with the machine, ensure that the connection is water
tight and the extension cable is suitably rated.
Start unit by turning the switches on the two units on. Four
capacity levels can be used by selecting low speed (I) or high
speed (II) on each unit.
If disturbing noise install a silencer, part no 3228.
After ca 700 working hours the pre-fi lter should be
pre-fi lter should be changed. If the suction capacity
does not increase after the pre-fi lter change then the
HEPA fi lter should also be changed.
Each fan has two speed settings which allow for economical
running, for example during the night.
Th e DC AirCube X2 can also be used to discharge air from
work places which must be kept under negative pressure.
Two 125 mm hoses can be attached to the fan outlet where
necessary.
exchanged, see Service on next page. When dust load
is extra high more frequent fi lter changes might be
necessary.