Lubrication - Makita AF505N Manuel D'instruction

Cloueur pneumatique polyvalent
Masquer les pouces Voir aussi pour AF505N:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
Selecting compressor
CFM
3
(ft
/min)
3
2
1
0
10
20
Nailing frequency (times/min)
014917
The air compressor must comply with the requirements
of ANSI B19.3.
Select a compressor that has ample pressure and air
output to assure cost-efficient operation. The graph
shows
the
relation
applicable pressure and compressor air output.
Thus, for example, if nailing takes place at a rate of
approximately 60 times per minute at a compression of
2
7.0 kgf/cm
G (100 PSIG), a compressor with an air
3
output over 2 CFM ( ft
Pressure regulators must be used to limit air pressure to
the rated pressure of the tool where air supply pressure
exceeds the tool's rated pressure. Failure to do so may
result in serious injury to tool operator or persons in the
vicinity.
Selecting air hose
004294
Use an air hose as large and as short as possible to
assure continuous, efficient nailing operation. With an air
2
pressure of 5.0 kgf/cm
internal diameter of over 6.5 mm (1/4") and a length of
less than 20 m (6.6 ft.) is recommended when the interval
between each nailing is 0.5 seconds. Air supply hoses
shall have a minimum working pressure rating of 10.7
2
kgf/cm
G (150 PSIG) or 150 percent of the maximum
pressure produced in the system whichever is higher.
30
40
50
between
nailing
/minute) is required.
G (70 PSIG), an air hose with an
CAUTION:
Low air output of the compressor, or a long or
smaller diameter air hose in relation to the nailing
frequency may cause a decrease in the driving
capability of the tool.

Lubrication

60
004295
To insure maximum performance, install an air set (oiler,
regulator, air filter) as close as possible to the tool.
Adjust the oiler so that one drop of oil will be provided
for every 50 nails.
When an air set is not used, oil the tool with pneumatic
tool oil by placing 2 (two) or 3 (three) drops into the air
frequency,
fitting. This should be done before and after use. For
proper lubrication, the tool must be fired a couple of
times after pneumatic tool oil is introduced.
007180
4
1. Pneumatic tool
oil

Publicité

Table des Matières
loading

Table des Matières