HGP−...−A−B(−G..)
9
Replacement and repairs
When replacing grippers:
Note that it is usually possible to replace grippers of the same type and with
S
the same gripping fingers without the need for adjustment.
When exhausting:
Please note
S Make sure that the gripper is not holding a work load.
In this way you can prevent a mass from sliding down.
10
Accessories
Designation
Safety start−up valve
One−way flow control valve
Non return valve, piloted
Proximity switches
Compensation reservoir
Adapter kit
Oil viscosity group 32 (as per ISO)
Grease
Fig. 21
Festo HGP−...−A−B(−G..) 0405b English
Metal on metal
Piston
Type
HEL−...
GRLZ−.../GRLA−...
HGL−...
SMT−8−.../SMT−8−...−B
VZS−...
HAPG−...
OFSW−32
Molycote DX
Molycote PG 75
27