en
4. Mark the positions for the fixing holes with
the aid of the template.
5. Determine dimension (X - Y); X = distance
between the cooking surface and the ceiling,
Y = distance between the cooking surface
and hood.
6. Screw the hanger bolts into the dowel until
approx. 20mm protrude. For standard
towers with quick assembly flanges, screw
the nuts onto the hanger bolts immediately.
7. Then guide the exhaust air hose
(extraction mode) and the connecting
cable down from the ceiling. The exhaust
air hose should be approximately 10cm
longer than the upper tower.
26
8. Slip the upper tower over the exhaust air
hose + electrical connecting cable. Then fas-
ten the upper tower to the ceiling using
washers and nuts, or using a quick assembly
flange. (Special tool type TZ 1000, item
no.55999800)
9. Slip the lower tower over the upper
tower and fix using adhesive tape.
10. Fasten the (extraction mode) exhaust
air hose to the cooker hood, making sure
that the hose is not bent.