en
min. 750 mm. If the manufacturer of the gas
cooking appliance specifies a greater
distance, this must be taken into consideration.
Gas cookers
Comply with the currently valid installation
regulations and instructions of the gas
appliance manufacturers. The extractor hood
may only be installed over gas hobs at a
minimum distance of 750 mm provided the
following nominal thermal loads (Hs) are not
exceeded:
Gas cookers
Load of one hotplate max.
Load of all hotplates max.
Load of the oven
Gas hobs
Load of one hotplate max.
Load of all hotplates
Installation instructions
for wall-mounte hood
Please fold out the illustrated pages
1. (For exhaust-air mode) Prepare suitable
exhaustair conduction in the wall or ceiling.
24
3.0 kW
8.3 kW
max. 3.9 kW
3.9 kW
max. 11.3 kW
2. Mark the positions for the following fixing
holes according to the indicated dimensions.
Dimensions which are not indicated depend
on the model and must be measured on the
hood. Ensure that there is a minimum dis-
tance between the hotplate and lower edge
of the extractor hood
2 holes (6 mm) for attachment of the upper
tower
2 holes (10 mm) for attachment of the
extractor hood
2 holes for additional attachment of
extractor hood if there are corresponding
fixing holes in the extractor hood.
3. Drill the holes and insert the corresponding
wall plugs flush with the wall:
4. Attach the bracket for the upper tower.
5. Screw woodtometal dowel screws into the
wall plugs (10 mm holes), leaving them
projecting by 20 mm.
the