Opening The Case; Assembling The Connection Cable - FEIG Electronic MWD BP-C Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

5.4 Opening the case

Please use a slot screwdriver for removing the case cover.
Prise up the case cover of the motion detector with the screwdriver at both the places marked in the picture.
Then remove the cover.
Fig. 3: Opening the case

5.5 Assembling the connection cable

Pull back by
approx. 1cm
Fig. 4: Cable mounting
FEIG ELECTRONIC GmbH
Manual
Connection, checking and maintenance
work on the open motion detector must
only be performed when it is disconnected
from the power. The points listed in the
"Safety notes" section must particularly be
observed.
Before opening the case cover, it must be
ensured that no external parts lying on the
cover can fall into the case.
The connection cable must be pushed through the
grommet before the insulation is removed.
Push the cable approx. 15-20cm through the
grommet and the case.
The cable hanging out of the case can be routed
and connected.
Store the cable in the rear part of the case before
you close the case.
IMPORTANT The connection cable must be
pulled back by approx. 1 cm in the grommet in
order to ensure the leak tightness and thus the
protection class IP 65 of the case.
Page 33 of 103
WARNING
ATTENTION
MWD BP_Handbuch_mehrsprachig_12.doc
MWD BP

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mwd bp-dMwd bp-u

Table des Matières