5. Slide in the dust cassette (12) until it engages .
6.2
Motor cleaning
Occasionally remove the dust cassette (12) again. If
dust accumulated at the air vents (on the inside of
the integrated dust extraction): vacuum thoroughly.
6.3
Replace worn suction head (7)
1. See page 3, fig. A.
Press and hold the release knob (14). Pull off the
suction head (7) upwards and remove.
2. Push in the new suction head (order no.:
6.23767) until it engages.
6.4
Replace worn filter (16)
1. See page 3, fig. B.
Position a Phillips screwdriver, as shown, and
turn a bit: this loosens the bracket of the
clamping flange (15) and the clamping flange
(15) can be removed.
If no screwdriver is available, the clamping
flange (15) can also be removed from its bracket
without tools.
2. Remove the old filter (16) and insert a new filter
(order no.: 6.23768).
3. See page 3, fig. C.
Attach the clamping flange (15) as shown:
suspend at the bottom from the pivot bearing
and press upwards until it engages.
7. Accessories
Use only genuine Metabo accessories.
Use only accessories which fulfil the requirements
and specifications listed in these operating
instructions.
See www.metabo.com or the catalogue for a
complete range of accessories.
8. Repairs
Repairs to electrical tools must only be carried
out by qualified electricians!
Contact your local Metabo representative if you
have Metabo power tools requiring repairs. See
www.metabo.com for addresses.
You can download a list of spare parts from
www.metabo.com.
9. Environmental Protection
Observe national regulations on environmentally
compatible disposal and on the recycling of disused
machines, packaging and accessories.
10. Technical Specifications
Explanatory notes on the specifications on page 3.
Changes due to technological progress reserved.
P
= Rated input power
1
V
= Suction power
l/min
m
= weight
8
H
= maximum working stroke or telescopic
max
stroke
T
= maximum drilling depth
max
D
= drilling bit diameter
The technical specifications quoted are subject to
tolerances (in compliance with the relevant valid
standards).
Direct current
During operation the noise level can exceed
80 dB(A).