Nº
Problem
2
No air comes out of the unit
while the machine is running.
3
The pump works but it is not
cold enough.
4
The pump does not work and
provides cooling.
5
The pump works but does not
circulate the water, or the
cooling pads contain very little
water.
6
Water spitting from the unit.
7
Undesirable smell
8
White sediments in the water
tank
Possible cause
Damaged engine.
Incorrect motor connection or
loose motor connection.
The thermal protection inside the
motor is working.
Dust filters are dirty or clogged.
The cooling pads are clogged.
The cooling pads are dry or do
not contain enough water while
the evaporative air cooler is
running
Relatively high relative humidity.
Damaged pump
Loose connection of pump motor.
Top water distribution tray
covered.
Clogged water supply hose or
pump filter.
The cooling pad remains out of
position.
Upper water distribution tray
covered.
The unit is placed in an area
where undesirable odors are
present, or algae are present in
the water tank.
The unit is in an area where
undesirable odors are present, or
algae are present in the water
tank.
Possible solution
Repair or replace the motor with
another of the same model.
Determine if the motor with
connections is in order or not.
Leave the unit turned off until the fan motor is cool
enough to use as usual.
Clean or repair the dust filters.
Clean or repair the cooling pads.
Leave the unit turned off until the fan
motor is cool enough to use as usual.
When the evaporative air cooler is used
for a prolonged period of time, the
humidity in the room will be very high,
so the evaporative cooler can not lower
the temperature as much as when the
humidity in the room is lower. Turn Cool
mode on and it will be lower.
Repair or replace the pump with a
pump of the same model.
Tighten the connection
Clean the upper water distribution tray.
Clean the water hose or remove the
clogged particles in the pump filter.
Place the cooling pad in the correct
position.
Clean the upper water distribution tray.
Clean the water tank and the cooling
pads.
Drain the tank and clean the cooling
platform more often.
Observations
Contact the technical
service.
17