To ensure sufficient air circulation, maintain a minimum distance of 50 mm between the rear
of the unit and the wall.
If the floor is uneven, the adjustable feet can be used to compensate and ensure optimum
stability. The unit should be installed at a slight angle in such a way that it leans to the rear:
this will ensure that the door will close automatically and cannot be left open by mistake.
Ensure, however, that both front feet are set to the same height.
Ventilation
The heated air around the unit must be able to circulate freely. Therefore, ensure that the
circulation is not obstructed.
Reversible door
The design provides for the door to be reversed, i.e. for right-hinged (default installation) to
become left-hinged. Additional blind covers are enclosed in a plastic bag in case the door
needs to be reversed.
- Remove the upper hinge cover (1).
- Use a suitable screw-driver to remove the
covers (5).
- Use a screw-driver to remove the two screws
(2) holding the upper hinge to the right side of
the housing.
- Carefully lift up the door and place it on a soft
surface to protect it from scratches.
- Remove the blind cover (9) for the hinge
mounting hole and fit it in the corresponding
place on the right-hand side of the door.
Ensure that the cover is firmly pushed down
into the hole.
- Pull off the two bolts (7) which hold the lower
hinge (4) in position on the right.
- Unscrew the adjustable foot (8) and re-fit it on the right-hand side.
- Replace the door in its new position. Ensure that the hinge pin is inserted into the guide
bushing (hole) on the lower part of the housing.
- Install the upper hinge (3) on the left-hand side, using the screws (2). Ensure that the
hinge pin is inserted into the guide bushing (hole) on the upper part of the housing.
- Install the lower hinge (4) loosely. The bolts (7) should be tightened only after the door
is closed and adjusted to its proper position.
- Replace the cover (5) in the corresponding holes on the right.
- Replace the hinge cover (1) on the upper hinge.
Controls
The unit is activated by connecting it to the mains. It is only switched off completely when
the plug is removed from the wall socket.
In position '0', the cooling function is switched off, though the appliance is still connected to
the mains.
The temperature in the cabinet can be adjusted by setting the temperature control. Turning
the control clockwise will decrease the temperature, while turning it anti-clockwise will
11