# format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
0. c0t1d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248>
/pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w2100002037e43542,0
1. c0t2d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107>
/pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w21000020374205a1,0
2. c7t16d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107>
/pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w500000e01002b7c1,0
3. c7t17d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107>
/pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w500000e0100357c1,0
4. c7t18d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107>
/pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w500000e010032331,0
5. c7t19d0 <drive not available: formatting>
/pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w500000e010032661,0
6. c7t20d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107>
/pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w500000e0100369e1,0
Specify disk (enter its number):
2. Notez le chemin d'accès au périphérique pour le nouveau disque d'initialisation.
Par exemple, pour le disque 2, qui est le nouveau disque d'initialisation dans ce cas,
le chemin de périphérique indiqué est /pci@8,600000/SUNW,qlc@1/fp@0,0.
Cette information est nécessaire pour réaliser
nouveau disque d'initialisation comme périphérique d'initialisation » à la page
Remarque – Le numéro qlc dépend du type d'hôte et de l'emplacement utilisés.
3. Indiquez le disque sur lequel le système d'exploitation est installé sur le disque
d'initialisation temporaire.
L'exemple suivant indique que le disque 2 est spécifié.
Specify disk (enter its number): 2
l'étape 4
Installation, connexion et test de l'adaptateur de bus hôte
de la section
« Pour définir le
33.