2. Installati on

2.1 Preparing the pool: water balance

These appliances are designed to disinfect pool water using the salt water chlorinati on functi on.
It is essenti al that the water balance and salinity (4 g/L) are checked and adjusted before installing the appliance. Making
sure that the water balance and salinity are correct from the very start will reduce the likelihood of encountering problems
on the fi rst days of operati on or during the season the pool is in use.
Even though it is an autonomous system, it is essenti al to regularly analyse the water to check the water
balance parameters and adjust them if necessary.
Unit
pH
/
mg/L
Free chlorine
or ppm
TA
°f
(alkalinity or
(ppm)
buff er power)
TH
°f
(level of calcium
(ppm)
carbonate)
Cyanuric
mg/L
acid
or ppm
(stabiliser)
g/L or
Salinity
kg/m³
Metals
mg/L
(Cu, Fe, Mn...)
or ppm

2.2 Installing the control box

• The control box must be installed in a dry venti lated technical room protected against frost, with no pool maintenance
products stored nearby.
• The control box must be installed at a distance of at least 2.0 m from the outside edge of the pool. Any additi onal local
legislati on in force concerning the installati on of the control box in the country concerned must be complied with.
• It must not be installed more than 1.5 metres from the cell (maximum cable length).
• If the box is fi xed to a post, a waterti ght panel must be fi xed behind the control box (350x400 mm minimum).
• Fix the support solidly to the wall or the waterti ght panel, and place the control box on it using the screws provided.
Recommended
To increase
values
Add pH+ or use
7.2 – 7.4
automati c regulati on
Increase chlorine
0.5 – 2
producti on or use BOOST
mode (Ei² Expert only)
8 – 15
Add alkaline corrector
(80 – 150)
10 – 30
Add calcium chloride
(100 – 300)
Only add cyanuric acid if
< 30
4
± 0
Add pH- or use
automati c regulati on
Reduce chlorine
Add hydrochloric acid
Add a calcium carbonate
sequestering agent or
carry out carbonate
Parti ally empty the pool
necessary
Leave as such or
Add salt
parti ally empty the pool
Add metal sequestering
/
Test frequency
To reduce
(in the season)
Weekly
Weekly
producti on
Monthly
Monthly
removal
Quarterly
and refi ll it
Quarterly
and refi ll it
Quarterly
agent
EN
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ei2 expert

Table des Matières