Overheat Protection - Qlima EOR 1515 LCD Manuel D'utilisation

Masquer les pouces Voir aussi pour EOR 1515 LCD:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

temperature is displayed and can be
changed as the temperature icon
blinking.
2. Use the + and - button to set the desired
temperature, from 13 to 30ºC.
3. The temperature icon will stop blinking
and the current room temperature will
appear after the desired temperature is
set.
4. Once the room temperature exceeds the
set temperature for over 10 seconds,
the heater will stop heating and the
temperature icon will blink.
5. Once the room temperature drops
1ºC below the set temperature, the
heater will start heating again and the
temperature icon on the display will stop
blinking.

OVERHEAT PROTECTION

This appliance has two levels of overheat
protection:
1. Automatic thermal cut-off
Switches off the heater in the event of
overheating or malfunction and resets
once the temperature drops to a normal
level
2. Thermal fuse
In the event that the automatic thermal
cut-off fails to operate, the heater has a
further safety device. This is a non-reset-
table switch which will require the unit
4
26
is

Publicité

Table des Matières
loading

Table des Matières