Connecting the fixture to 12 V
The already installed lamp means the fixture is immediately ready for
use. Therefore you do not need to install the lamp first.
Step 1
Remove the butterfly screw from the toothed coupling of the housing.
Attach the ground stake to the lamp by placing the two toothed
coupling halves on top of one another. Place the cable in the recess
intended for this purpose. Stick the butterfly screw through the hole in
the ground stake and tighten it. Decide how you want your lamp to be
positioned before you tighten the butterfly screw fully. (Fig. 1)
Step 2
Join the Easy-Lock connector to the main cable. (Fig. 2)
a. Clamp the cable duct on top of the main cable.
b. Place the cable duct (with the cable at the bottom) in the Easy-
Lock connector.
c. Tighten the threaded cap on the Easy-Lock connector. This will
cause the contacts to be pushed through the insulation on the
cable. In tightening the cap, a little gel is applied to the contacts in
the Easy-Lock connector. This serves to protect the contacts
against moisture. A little gel may possibly come out of the Easy-
Lock connector: so after installation (and/or before a meal), wash
your hands with soap and water, and avoid the gel coming into
contact with your eyes.
Step 3
Connect the power cable to the fixture by connecting the mini-
connector. (Fig. 3)
If the lamp does not work correctly, check that the Easy-Lock connec-
tor is properly connected to the main cable. Do the same for the mini-
connector. Repeat steps 2 and 3. When the fixture is connected to the
main cable also check that the contacts of the Easy-Lock connector
are not bent. If you have any problems, contact your dealer.
General maintenance advice
We advise wiping the fixture down at least once a year using a clean
cloth and warm water.
Accessories
Accessories are available for this armature. See www.in-lite.com.