8.1.1
Dangerous substances
WARNING
Any harmful products that are consumed during the activities, must be collected and
disposed of in a environmentally responsible way.
8.2
Maintenance materials
/i
Application
Steel parts
Hinge pins
Long-term preservation
Contact the Holmatro dealer for information on spare parts.
8.3
Maintenance schedule
This schedule is an average. Depending on the intensity of use of your equipment, Holmatro can
provide a specific maintenance schedule for you.
/i
Oil
Blades
Snap ring of hinge pin
Hinge pins
Centre bolt
Accessories
Lock pins for accessories
Carrying handle
8.4
Maintenance activities
8.4.1
General
•
Check the operation of the unit.
•
Check the unit for damage and leaks. If the unit doesn't work properly and/or leaks, have it repaired
by a Holmatro Certified Technician.
HCT5111 (RH)(ST)/HCT5117 (RH)(ST)
Type of maintenance material
WD-40 preservative oil
Teflon lubricating oil
Tectyl ML from Valvoline
Check
Check
Check
Lubricate
Check
Lubricate
Check
Check
Lubricate
Check