Terminaisons verticales avec trois 90 ° coudes
Deux 90 ° Vertical et un coude horizontale de 45 ° ou 90 °
La résiliation doit relever de la zone ombrée indiquée le graphique. Utilisez la position indiquée réducteur.
40' max (12m)
35 feet (10.5m)
30 feet (9m)
25 feet (7.5m)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
© Travis Industries
Installation
NOTE:
Horizontal sections require a 1/4" (0.250mm)
rise every 12" (305mm) of travel.
(for qualified installers only)
Restrictor
Position # 5
NOTE:
Restrictor positions are based upon lab
tests. The ideal restrictor position may
vary slightly, especially when the
termination is near a
demarkation line.
Restrictor
Position # 1
4090717
15
40' max (12m)
35 feet (10.5m)
30 feet (9m)
25 feet (7.5m)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
100-01225_000