Hansa 5228 9103 Instructions De Montage Et D'utilisation page 19

Table des Matières

Publicité

Für den Installateur
For the Plumber
Pour l'installateur
Para el instalador
1
stop ring
stop post
(downward)
Close service stops:
1
- Remove the wall template.
- Close the hot and cold water supplies.
Remove stop ring:
2
- Remove stop ring (1) note position.
Turn cartridge for back-to-back installation:
3
- Remove the four cover set screws (2) and the valve cover (3) with O-ring (4).
- Pull the cartridge out. Do not damage the O-ring seals.
- Rotate the cartridge 180° turning it upside down. Place it into the valve body. Note position of hot („H")
and cold („C") markings on the cartridge:
„H" hot will now be on the right and „C" cold on the left. Two alignment pins located on the cartridge
must sit in the locating holes within the valve body. Cartridge is correctly engaged when pushing the
cartridge, it will not rotate.
- Put the O-ring (4) on the valve cover. Make sure the surface of the valve cover, on which the O-ring
will sit, and the O-ring are both clean.
- Position the valve cover with stop facing down. Seat the cover to the body. Do not pinch the O-ring.
The assembly should fit together with a minimum of pressing force.
- Tighten up the cover screws diagonally, first lightly and then more firmly.
Fix stop ring on closed position:
4
- Close the valve by turning the cartridge stem clockwise.
- Position the stop ring on the stem as shown in figure 4.
- Install plastic adapter with screws.
Back-to-back installation
1 8 0 °
4
3
cartridge stem
2
stop post
(downward)
stop ring
19
close

Publicité

Table des Matières
loading