Do not machine any materials that present a danger to health
(e.g. asbestos).
When working in walls ceiling, or oor, take care to avoid electric
cables and gas or waterpipes.
Switch the device o immediately if the insertion tool stalls! Do
not switch the device on again while the insertion tool is stalled,
as doing so could trigger a sudden recoil with a high reactive force.
Determine why the insertion tool stalled and rectify this, paying
heed to the safety instructions.
Possible causes can be:
• it is tilted in the workpiece to be machined
• breakage of the material to be used
• the power tool is overloaded
Do not reach into the machine while it is running.
The insertion tool may become hot during use.
WARNING! Danger of burns
• when changing tools
• when setting the device down
Chips and splinters must not be removed while the machine is
running.
Clamp your workpiece with a clamping device. Unclamped
workpieces can cause severe injury and damage.
Always disconnect the plug from the socket before carrying out
any work on the machine.

MAINS CONNECTION

Connect only to a single-phase AC current supply and only to the
mains voltage speci ed on the rating plate. Must only be used
from sockets with earth wire.
Appliances used at many di erent locations including wet room
and open air must be connected via a residual current device (FI,
RCD, PRCD) of 30mA or less.
Only plug-in when machine is switched o .
Keep mains lead clear from working range of the machine. Always
lead the cable away behind you.
Before use check machine, cable, safety harness and plug for any
damages or material fatigue. Repairs should only be carried out
by authorised Service Agents.

SPECIFIED CONDITIONS OF USE

The pneumatic hammer can be universally used for hammer
drilling and chiselling in stone and concrete.
MAINTENANCE
Always disconnect the plug from the socket before carrying out
any work on the machine.
If the replacement of the supply cord is necessary, this has to be
done by the manufacturer or his agent in order to avoid a safety
hazard.
The ventilation slots of the machine must be kept clear at all times.
Use only Milwaukee accessories and Milwaukee spare parts.
Should components need to be replaced which have not been
described, please contact one of our Milwaukee service agents
(see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please
state the Article No. as well as the machine type printed on
the label and order the drawing at your local service agents or
directly at: Techtronic Industries GmbH, Max-Eyth-Straße 10,
71364 Winnenden, Germany.

EC DECLARATION OF CONFORMITY

We declare under our sole responsibility that the product
described under "Technical Data" ful lls all the relevant
provisions of the directives
2011/65/EU (RoHS)
2006/42/EC
2014/30/EU
and the following harmonized standards have been used.
EN 60745-1:2009 + A11:2010
EN 60745-2-6:2010
EN 55014-1:2017
EN 55014-2:2015
EN 61000-3-2:2014
EN 61000-3-3:2013
EN IEC 63000:2018
Winnenden, 2019-01-31
Alexander Krug / Managing Director
Authorized to compile the technical le
Techtronic Industries GmbH
Max-Eyth-Straße 10, 71364 Winnenden, Germany