6. Operation
Example:
interruption (error
code 3) of wires 1,
2, and 3.
press Step Key
à If
installation
detected the conductor LED (F)
of the respective poles will light
red and the error code digit
lights in the numeric display (B).
Ä If more than one installation
error is detected, press the Step
Key (H) to display the other
errors.
Å After the last error is displayed
a flashing digit is shown in the
numeric display (B). This digit
stands for the number of the
connected Test Box.
Æ If you press the Step Key (H)
again as long as the Test Box
number is flashing, the error
list is shown a second time, see
item Ã.
Ç For repeated testing continue
as described under item À.
The KAPRi plus Mainframe can be
turned off at any time by pressing
the Start Key.