CDVI CAA Manuel D'installation page 17

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION MANUAL
CAA - CBB
Self-contained Keypads - braille keys
illumination. The green led lights on
to confirm the programming.
4. Press
2 for output time of relay 2
- Green LED lights on for 1 second.
- Enter the duration in seconds.
E.g. : From 01 for 1 second to 99
for 99 seconds or enter 00 for a permanent
illumination. The green led lights on
to confirm the programming.
5. Press
3 for output time of relay 3
- Green LED lights on for 1 second.
- Enter the duration in seconds.
6. Press # to exit from the programming
mode.
The red LED lights off to confirm that the keypad
is in stand-by operating mode.
Red LED flashing 4 times indicates
a data computing error.
F. Resetting the master code
- In normal operation, place a jumper at P2
- Green LED lights on to confirm entry
in programming mode.
2. Enter #0 for the key-in keypad time.
- Green LED lights on for 1 second.
- A beep is emitted.
- Wait for the green LED to light off.
- Remove the jumper.
- The master code is again 1 2 3 4 5 6
in 6 digits, 1 2 3 4 5 in 5 digits
or 1 2 3 4 in 4 digits.
G. Changing the code by the user
To enable the function programming the code
by the user place jumper on P3. Remove the
jumper to disable the function.
1. Enter the old user code.
- The relay is activated.
- Green LED lights on.
2. Enter the 2-digit sub master code
- The red LED lights on to authorise
the modification.
3. Enter the new user code.
- Green LED lights on for 1 second
to confirm the new code.
- The red LED lights off.
Check the new user code to be sure
of the modification.
H. Setting a sub master code
1. Enter the master code twice.
- For the first use the factory master code
is: 1 2 3 4 5.
- The red LED's light on to confirm entry
in programming mode.
2. Press
7 to input modification digits
for group 1 user codes.
- Green LED lights on for 1 second.
- Enter the two digits of the modifications.
3. Press
8 to input modification digits
for group 2 user codes.
- Green LED lights on for 1 second.
- Enter the two digits of the modifications.
4. Press
9 to input modification digits
for group 3 user codes.
- Green LED lights on for 1 second.
- Enter the two digits of the modifications.
5. Press # to exit from the programming mode.
The red LED lights off to confirm that the keypad
is in stand-by operating mode.
I. Programming the audible signal
The audible signal is always audible during
programming. It is also audible on a command
to open, following the recognition of a code.
By default, when the opening code is entered,
no "key" beep is audible. It is possible to authorise
key beeps by proceeding as follows:
1. Enter the master code twice.
- For the first use, the factory
master code is: 1 2 3 4 5.
- Red LED lights on to confirm
entry in programming mode.
2. Press
.
- One beep is emitted.
Press 0 to disable the audible signal
during a keypress.
EN
-
cdvi.com
17
cdvigroup.com

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cbb

Table des Matières