Operating Elements And Connections; Safety Notes - IMG STAGELINE MFX-16 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
Please unfold page 3. Then you can al-
ways see the operating elements and
connections described in the figures.
1 Operating Elements and
Connections
1 Control INPUT for the input amplification
2 Control MIX for adjusting the ratio of orig-
inal signal and effect signal at the output
(adjustment of effect intensity): the furth-
er the control is turned clockwise, the
higher is the share of the effect signal
3 Control OUTPUT for adjusting the output
level
4 Overload LED SIGNAL; lights up in case
of overload of the input [in this case turn
back the control INPUT (1) correspond-
ingly]
5 Selector switch EFF SELECT for effect
selection
6 POWER LED
7 Selector switch VARIATIONS for para-
meter adjustment of the effect selected
with the switch EFF SELECT (5); for
each effect, 16 adjustments are available
(for this purpose see the list of effects on
pages 28 to 33)
8 Connection for power supply (9 V~/
300 mA) via the supplied plug-in power
supply unit
9 6.3 mm mono jack REMOTE for connect-
ing a foot switch or momentary action
foot switch for switching on and off the ef-
fect (bypass function)
10 6.3 mm jacks OUTPUT for the LEFT and
RIGHT output channels; unbalanced
11 6.3 mm jacks INPUT for the LEFT/
MONO and RIGHT input channels; un-
balanced
Note: In case of mono signal sources,
only connect the left jack LEFT/
MONO. The signal will be inter-
nally switched to the right and left
channels.

2 Safety Notes

The effect unit and the supplied plug-in power
supply unit correspond to the directive for
electromagnetic compatibility 89/336/EEC.
The power supply unit also corresponds to
the low voltage directive 73/23/EEC.
Attention!
The power supply unit is supplied with haz-
ardous mains voltage (230 V~). Leave ser-
vicing to skilled personnel only. Inexpert
handling may cause an electric shock haz-
ard. Furthermore, any guarantee claim will
expire if the effect unit or the power supply
unit has been opened.
The effect unit and the power supply unit
are suitable for indoor use only. Protect
them against dripping water and splash
water, high air humidity, and heat (admissi-
ble ambient temperature range 0 – 40 °C).
Do not operate the effect unit or immedi-
ately disconnect the power supply unit
from the mains socket
1. if there is visible damage to the effect
unit or to the power supply unit,
2. if a defect might have occurred after a
unit was dropped or suffered a similar
accident,
3. if malfunctions occur.
In any case the units must be repaired by
skilled personnel.
For cleaning only use a dry, soft cloth;
never use chemicals or water.
No guarantee claims for the unit or liability
for any resulting personal damage or ma-
terial damage will be accepted if the effect
unit or the power supply unit is used for
other purposes than originally intended, if
it is not correctly connected, operated, or
not repaired in an expert way.
If the effect unit and the power supply unit
are to be put out of operation definitively,
take them to a local recycling plant for a
disposal which is not harmful to the envi-
ronment.
GB