WARNING:
be used with a power supply unit
supplied by Husqvarna.
When connecting the power supply, only use
a wall socket that is connected to an earth
fault-breaker (RCD).
WARNING:
Install only to an earth-fault breaker
(RCD) when connecting the power
supply to the wall socket. For USA/
CANADA: Use a covered Class A
GFCI receptacle (RCD) that has an
enclosure that is weatherproof with
the attachment plug cap inserted or
removed.
WARNING:
supply must be changed or
tampered with. The low voltage
cable must not be shortened or
extended.
Low-voltage cables of different lengths are
available as accessories.
WARNING:
cable and extension cable must be
outside the work area to avoid
damage to the cables.
WARNING:
circumstances mount the power
supply at a height where there is a
risk it can be submerged in water (at
minimum 30 cm / 12" from the
ground). It is not permitted to place
the power supply on the ground.
10 - Installation
The product is only to
Risk of Electric Shock.
No parts of the power
The power supply
Do not under any
min 30 cm / 12"
WARNING:
disconnect the charging station, for
instance before cleaning the
charging station or repairing the loop
wire.
WARNING:
cable and adjust the cutting height
so that the blades on the blade disc
can never come in contact with the
cable.
WARNING:
damage to electrical components,
disconnect all connections to the
charging station (power supply,
boundary wire and guide wires) if
there is a risk of a thunderstorm.
WARNING:
the power supply. Condensed water
can harm the power supply and
increase the risk of electrical shock.
For more instructions on how to do a proper
installation, refer to chapter
complete Operator's manual on Husqvarna's
website www.husqvarna.com.
3.2 Control panel
All commands and settings for the product are
made via the control panel. All functions are
accessed via a number of menus.
The control panel consists of a display and a
keypad. All information is shown on the
display and all input is done using the buttons.
1352 - 001 - 09.12.2019
Use the plug to
Place the low voltage
To reduce the risk of
Do not encapsulate
Installation in the