WIKA N-10 Mode D'emploi page 7

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7. Starting, operation
Specifications
Model N-10 / N-11
Materials
Wetted parts
»
Model N-10
»
Model N-11
Case
Internal transmission fluid
Power supply U
U
in VDC
B
B
Signal output and
maximum ohmic load RA
R
in Ohm
A
Response time (10 ... 90 %)
ms
Dielectric strength
VDC
Accuracy
% of span
3)
Including non-linearity, hysteresis, zero point and full scale error (corresponds to
error of measurement per IEC 61298-2).
Adjusted in vertical mounting position with lower pressure connection.
Non-linearity
% of span
Non-repeatability
% of span
1-year stability
% of span
Permissible temperature of
Medium
4)
Ambience
4)
Storage
4)
Also complies with EN 50178, Tab. 7, Operation (C) 4K4H, Storage (D) 1K4,
4)
Transport (E) 2K3
1 WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio N-10, N-11
(Other materials see WIKA diaphragm seal program)
Stainless steel (> 25 bar stainless steel and Elgiloy
Stainless steel
O-ring: NBR {FPM/FKM or EPDM}
Stainless steel
Synthetic oil (not for N-10 with pressure ranges > 25 bar)
10 < U
≤ 30 with signal output 4 ... 20 mA, 2-wire
B
10 < U
≤ 30 with signal output 1 ... 5 V, 3-wire
B
{low power 6 < UB ≤ 30}
≤ (U
4 ... 20 mA, 2-wire
R
– 10 V) / 0.02 A
A
B
1 ... 5 V, 3-wire
R
> 10 k
A
≤ 1
500
≤ 0.25
(BFSL)
≤ 0.5
3)
≤ 0.2
(BFSL) according to IEC 61298-2
≤ 0.1
≤ 0.2
(at reference conditions)
-30 ... +105 °C
-22 ... +221 °F
-30 ... +80 °C
-22 ... +176 °F
-30 ... +105 °C
-22 ... +221 °F
GB
7. Starting, operation
Specifications
Compensated temp range
Temperature coefficients within
compensated temp range
®
)
Mean TC of zero
Mean TC of range
CE- conformitiy
Pressure equipment directive
EMC directive
Directive ATEX of equipment
intended for use in potentially
explosive atmospheres
Ex-protection
Ignition protection type
Conformity specifications
Power supply UB
Medium
Ambient
»
»
Storage
RF-immunity
Burst
Shock resistance
Vibration resistance
WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio N-10, N-11
Model N-10 / N-11
0 ... +80 °C
% of span
≤ 0.2 / 10 K
% of span
≤ 0.2 / 10 K
97/23/EC
89/336/EEC emission (class B) and immunity according to EN 61 326
94/9/EC
ATEX
II 3G EEx nA II
II 3D IP65 T80°C
EEx nA II 4
VDC
30
-30 ... +105 °C
-22 ... +221 °F
M12x1
-25 ... +90 °C
-13 ... +194 °F
Flying leads
-30 ... +80 °C
-22 ... +176 °F
-30 ... +105 °C
-22 ... +221 °F
V/m
10
KV
4
g
1000 according to IEC 60068-2-27 (mechanical shock)
g
20 according to IEC 60068-2-6
GB
32 ... +176 °F
(< 0.4 for pressure range ≤ 0,25 bar)
EEx nA II T5
EEx nA II T6
30
30
-30 ... +80 °C
-30 ... +60 °C
-22 ... +176 °F
-22 ... +140 °F
-25 ... +80 °C
-25 ... +60 °C
-13 ... +176 °F
-13 ... +140 °F
-30 ... +80 °C
-30 ... +60 °C
-22 ... +176 °F
-22 ... +140 °F
-30 ... +105 °C
-30 ... +105 °C
-22 ... +221 °F
-22 ... +221 °F
(vibration under resonance)
1

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

N-11

Table des Matières