Maintenance & service
o Cleaning
The cleaning of internal must be carried out periodically to optimize light output. Cleaning frequency depends
on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause
greater accumulation of dirt on the fixture's optics.
Clean with soft cloth using normal glass cleaning fluid.
Always dry the parts carefully.
Clean the external optics at least every 20 days.
o Troubleshooting
Following are a few common problems that may occur during operation. Here are some suggestions for easy
troubleshooting:
The fixture does not work, no light
Check the connection of power and main fuse.
o
Measure the mains voltage on the main connector.
o
Not responding to DMX controller
Diamond Plus User's Manual Ver. 1.00
Forward, from fast to slow(with
17CH)
Dynamic
pattern speed
Reverse, from slow to fast(with
17CH)
Back color R
dark to bright linear dimming
Back color G
dark to bright linear dimming
Back color B
dark to bright linear dimming
Back color W
dark to bright linear dimming
Reset
NO
Reset within 5s
R1 LED dimmer R1 LED dimming
G1LED dimmer
G1 LED dimming
B1 LED dimmer B1 LED dimming
W1LED dimmer W1 LED dimming
......
......
R19 LED
R19 LED dimming
dimmer
G19 LED
G19 LED dimming
dimmer
B19 LED
B19 LED dimming
dimmer
W19 LED
W19 LED dimming
dimmer
0--127
128--255
0-255
0-255
0-255
0-255
0-250
250-255
0-255
0-255
0-255
0-255
......
0-255
0-255
0-255
0-255