Pin Assignment - Emerson AVENTICSTM PE5 Notice D'instruction

Capteur de pression
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
[MPa]
[kPa]
[bar] Dp
1
1000
10
0,8
800
8
0,6
600
6
0,4
400
4
0,2
200
2
0
0
0
0
1
2
3
4
Fig. 18: Permissible period T (gray area) as a function of the pressure fluctuation
Δp
1.
2.
Fig. 19: Connecting the push-in fitting
Fig. 20: UL Recognized Component Mark for Canada and the United States
U [V]
11,8
10,0
0
U [V]
11,8
10,0
0
UL
MBA
Fig. 21: Behavior of the analog voltage outputs if levels exceed or fall below the
measuring range
AVENTICS
TM
PE5 | R412010843-BAL-001-AF | English
Dp [psi]
145
116
87
58
29
0
5
T[s]
p
p
OL
MBE
I [mA]
20,5
20,0
4,0
3,8
I [mA]
20,5
20,0
4,0
3,8
UL
MBA
Fig. 22: Behavior of the analog current outputs if levels exceed or fall below the
measuring range
P = pressure
P
0,Start
p
1
∆p
p
2
t
t
0
1
Timer A
Fig. 23: Leakage characteristic
Internally stored pa-
rameters

2 Pin Assignment

4
3
1
2
Fig. 24: Pin assignment, 4-pin
Pin
Assignment
1
24 V power supply (+)
2
Digital switch output 2 (PNP/NPN/push-pull, switchable)
3
0 V power supply (-)
4
Digital switch output 1 (PNP/NPN/push-pull, switchable)
Pin
Assignment
1
24 V power supply (+)
2
Analog output (4 to 20 mA/0 to 10 V)
3
0 V power supply (-)
4
Digital switch output 1 (PNP/NPN/push-pull, switchable)
p
p
OL
MBE
P
0,End
t [sec.]
t
2
t
out
∆t
Adjustable parameters
Output value
V = volume
P
1 UB
2 OUT2
3 0V
4 OUT1
P
1 UB
2 analog
3 0V
4 OUT1
16