Les langues disponibles

6) Supply frequency
7) Current used when operating
8) Electrical power used when operating during refrigeration phase (Fans+hot cables+lighting)
9) Electrical power used when operating during defrost phase (Armoured resistances+hot
cables+fans+lighting)
10) Lighting power (where applicable)
11) Net display surface
12) Type of refrigerant fluid with which the system functions
13) Mass of refrigerant gas with which each system has been loaded (only for units with built-in motor)
14) Environmental climatic class and temperature of reference
15) Humidity protection class
16) Unit manufacturing order number
17) Unit production order number
18) Unit year of production
To identify the unit when requesting technical assistance, you need simply provide the following:
the product name (Fig. 2 - 2); the serial number (Fig. 2 - 4); the order number (Fig. 2 - 16).

5. Transport (Fig. 3)

The cabinets are supplied on a wooden support fixed to the base for movement with forklift trucks.
Always position the forks at the point specified on the wooden support to avoid the risk of
overturning. Use a manual or electrical forklift truck that is suitable to moving the cabinet in question.
It must have a nominal capacity of at least 1,000 kg.

6. Acceptance and first cleaning

Upon acceptance of the unit:
- Ensure that the packaging is intact and there is no obvious damage;
- Unpack, ensuring that the unit is not damaged;
- Check that all parts of the unit are intact;
- Should damage be reported, call the supplier immediately;
- Clean for the first time using neutral products. Dry with a soft cloth. Do not use any abrasive
substances or metal sponges;
- DO NOT use alcohol to clean the methacrylate parts (Plexiglas).
For correct disposal of the packaging, please consider that it consists of: Wood - Polystyrene -
Polythene - PVC - Cardboard.
In accordance with Directive EEC 94/62, we declare the suitability of the above-specified materials.

7. Installation and environmental conditions(Fig. 3)

To install, please keep to the following rules:
- Do not position the unit:
- in environments with the presence of explosive gaseous substances;
- outdoors and therefore where there are atmospheric agents;
- near heat sources (direct sunlight,heating systems, incandescent lights, etc.)
- near air currents (near doors, windows, air-conditioning/heating systems, etc.) exceeding speeds of 0.2
m/sec.
- Remove the wooden supports at the base (used for transport) and assemble the adjustable feet (Rif. 2),
positioning them in such a way as to bring the unit to a horizontal position. Use a spirit level (Rif. 1) to
check this.
- If the unit is moved, repeat the level control.
- Before connecting the unit up to the electricity, ensure that the plate data corresponds to the
characteristics of the electrical system to which it is to be connected.
- For correct unit operation, the environmental relative humidity and temperature must be in line with the
parameters specified by standards EN ISO 23953 - 1/2, namely Climatic Class 3 (+25°C; Rel. Humidity
60%).
N.B. All these operations should be performed by specialised technical personnel only.

8. Multiplexing of cabinets (Fig. 6)

MULTIPLEX KIT
Pos. Name
1
Alignment plug Ø 4x80
05060103 01 18/05/2010
Code
It
02940652 10
Aries115GA - Aries150GA