Rear View; Important - Dyson AB12 Guide D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
EN
Contents.
Main unit x 1
Service tool x 1
Side bracket and
seal assembly
3.2
Side cable entry.

ImPortaNt

Cable entry can be either from the
left or the right. Decide which before
you start.
The unit is designed to have only one
side cable entry point.
NotE: If the side entry option is
chosen, a fifth hole will need to be
drilled in the wall.
Make sure you work on the correct
side for the installation. The break-
out on the main body must match up
with the bracket on the backplate.
Once the break-out panel on the
main body has been removed there
is no option to swap sides.
1
Unpacking.
Backplate
Main body
Use caution when removing the casing.
The casing may have sharp edges/
corners which may cut or cause harm.
1. Place the main body on a cloth to
avoid marking its surface.
2. Remove the (2) security screws from
the main body, using the service tool
provided. Store safely.
3. Lift the backplate out of the main
body.
4. If cable entry is to be from the rear,
remove the rubber cable grommet
from the rear cable entry hole. Store
safely.
Left

REAR VIEW

1. Ensure you work only on the side of
the fascia that you have chosen for
the cable entry point.
2. Use pliers to carefully nip out only
one pre-marked break-out panel in
the correct side of the main body.
Align to one of the edges and break
off an initial part of the panel.
3. Align to the other edge and break
off an initial part of the panel.
4. Break off the whole part from the
centre.
5. Clean up any excess plastic.
6. Drill holes.
CaUtIoN: Do not use the backplate
as a guide when drilling. Ensure no
pipe work (gas, water, air) or electrical
cables, wires or ductwork are located
directly behind the drilling/mounting
area.
7. Pull the electricity supply cable
through the side bracket and side
bracket seal as shown. Ensure
2
Positioning.
Side cable
entry
CaUtIoN
Before installation decide if the cable
entry is to be from (3.1) the rear or
(3.2) the side. Follow the relevant
instructions.
NotE
This product is not recommended for
mounting onto porous wall surfaces
(e.g. plaster) without a back panel,
to avoid discolouring or damage to
unprotected walls. (A back panel for this
product is available from Dyson.)
right
REAR VIEW
that cable is long enough to route
correctly through the backplate to
the terminal block. (Note: cable
length will be different for left and
right side entries.)
NotE: Ensure suitable cable gland/
conduit connector is used (not
provided) for the installation.
14
Side cable
entry
Rear cable
entry
Recommended height measurements are
from the floor.
1300mm adult male.
1265mm adult female.
928mm children 5–8 years old.
1028mm children 8–11 years old.
1108mm children 11–14 years old.
1050mm wheelchair user.
CaUtIoN: Do not use the backplate
as a guide when drilling. Ensure no
pipe work (gas, water, air) or electrical
cables, wires or ductwork are located
directly behind the drilling/mounting
area.
NotE: If the side entry option is chosen,
a fifth hole will need to be drilled in the
wall. See step 3.2.
1. Select the appropriate height.
Recommended heights are shown,
but may need to be adjusted for
each individual installation.
2. Minimum clearances are: above,
30mm; sides, 220mm. There should
be no obstruction between the unit
and the floor.
3. Measure the location on the wall. If
cable entry is to be from the rear, the
6mm
● Primary fixing locations (x4).
Do not use countersunk screws.
5th hole for side entry
Fixing the backplate to the wall.
Fit the main unit securely to the wall
using the appropriate fixings for
the wall type and weight of the unit.
Slide the side bracket into the recess
between the wall and the backplate.
Screw to the wall and secure with the
appropriate fitting.
Do not use counter-sunk screws.
24mm
to top of
fascia
211mm