ATTENTION!
In order to avoid a hazard due to inadvertent
resetting of the thermal cutout, this appliance
must not be supplied through an external
switching device, such as a timer or
connected to a circuit that is regularly
switched on and off by the utility.
ATTENTION!
Connection only to fixed installed cables! The
hardwired electrical installation must be
provided with a disconnect device with a
contact grap of at least 3 mm at each pole
(e.g. automatic circuit breaker)!
2
Technical data
Connection voltage: 1/N/PE~, 230 V, 50 Hz
Protection type:
IP20
Protection class:
I (with protective conductor)
Type
Heat out-
Width
put (W)
(mm)
DX 410
1000
575
DX 415
1500
575
DX 420
2000
575
DX 425
2500
695
DX 430
3000
695
3
Mounting, Installation, Minimum Clearances
The heating device may only be installed as shown, i.e.
on a horizontal, even surface. Using it on deep-pile car-
pets is not permitted. Please use caution when install-
ing it in front of flammable objects. Installation below a
wall socket is not permissible. Minimum clearances
must be observed.
In addition, a minimum clearance of 500 mm between
flammable objects e.g. curtains, towels or heat-sensi-
tive plastics and the front of the unit must be main-
tained.
www.dimplex.de/en
Height
Depth
Weight
(mm)
(mm)
(kg)
350
124
4,1
350
124
4,1
350
124
4,1
350
124
4,8
350
124
4,8
DX410_430_gb · 04/15/B
DX 410, DX 415, DX 420, DX 425, DX 430
The heating device must be aligned horizontally and in-
stalled on a vertical wall (see illustration).
Make sure that the inflow and outflow of air at the top
and bottom of the device are unimpeded
It is not permissible to install the device in protection
zones as defined in VDE 0100 part 701.

3.1 Wall mounting

ATTENTION!
The original wall mounting bracket supplied, located at
the back of the heater, must be used.
Remove the bracket from the back of
the device by pressing the springs on
each side.
Drill the fixing holes for the wall mount-
ing bracket.
Firmly secure bracket to the wall using suitable
screws.
Insert heater in wall bracket making use of the slots
on the back of the heater. Snap heater in place at
the top of the wall bracket.
Type
Heat output (W)
DX 410
1000
DX 415
1500
DX 420
2000
DX 425
2500
DX 430
3000
4
Electrical Connection
The voltage specified on the type plate must match the
local mains voltage.
The device plug must always be accessible.
The heaters are fitted with a power supply cable with-
out plug. The supply cord must be connected to a con-
nection box dedicated to the heater.
.
A (mm)
354
354
354
476
476
EN-7