Pentair Jung Pumpen BAUFIX 100 Instructions De Service page 9

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
ENGLISH
Accessory guide rail system GR32
For the pumps U3KS, U5KS and U6KS is as an accessory guide
rail system available that can be mounted in the Baufix. A sim-
ple pull out and lowering the pump is possible.
Accessory alarm device
The alarm device signals an excessive high water level. It can
be installed subsequently. The cable is pulled through the vent
pipe and sealed in the same way as the pump cable. The alarm
unit should be connected to a separate electric circuit, to en-
sure the operation in case of a pump fault. Alternatively it can
be equiped with our 9V-rechargeable battery for off the line
operation.
Accessory special ventilation
If the ventilation over the roof level is not possible, alternatively
the special ventilation consisting of a ventilation screen and 3
activated carbon filters can be installed with a T-piece in the
cable pipe. An assembly instruction accompanies the special
ventilation.
MAINTENANCE
The tank, the float switches and the foot strainer of the pump
should be inspected regularly and cleaned if necessary.
To service the pump, please refer to the separate operating
instruction.
NOTICE! Always grease the screws before using them to close
the cover plate and ensure the correct position of the profiled
seal.
9

Publicité

Table des Matières
loading

Table des Matières