GB
With a spraying width of 50 cm, a length of 2 m
equals a sprayed area of 1 m
Speed of spraying:
Quantity sprayed per minute x distance
Quantity of spray per m
0.42 l x 2 m
min. x 0.06 l
The figures on which this sample computation of the
dosage and the quantity of spray compound required
per m
2
are based have been assumed for that purpose.
When using the sample computation, the figures given
by the manufacturer of the respective spray compound
must be used.

Spraying

Operate the pump lever five or six times from top
to bottom. This will fill the air chamber and the
spray line with spraying agent and produces the
working pressure required for spraying.
Press down the operating lever on the quick-acting
valve to start spraying. Spraying stops at once if
you release the operating lever.
The spraying pressure at the nozzle is influenced by
the speed of the pumping-up operation. This can be
read off from the pressure gauge. The optimum
spraying pressure is between 1.5 and 2.5 bar.
Aim to achieve even coverage of the object when
spraying.

Troubleshooting

Malfunction
The hose connection to the sprayer
does not seal properly
No liquid comes out of the nozzle
after pumping
The spray pattern of the nozzle is
unusual
8
2
.
2
= 14,00 m/min.
Cause
The spray line has not been
screwed in tightly to the pump or
the quick-acting valve
Clean the filter or the nozzle
The nozzle is partially clogged
Be aware of the direction of the wind. Do not spray
into the wind.
The optimum distance from the nozzle to the object
being sprayed is 40-50 cm.

Emptying and Maintenance

Thoroughly clean out the unit with water each time
after it has been used (rinse it out several times)
and leave it open to dry out.
Cleaning of the strainer tube in the quick-acting
valve:
Loosen the locking nut from the trigger control
valve and take the hose nozzle with sieve from the
trigger control valve.
The gasket in the cover of the container and all
other mobile parts have to be lubricated regularly
with resin and acid-free grease.
It is recommended that you use GLORIA special
activated charcoal, item number 263.0000, for
optimum cleaning of the sprayer and to ensure that
any residues of the spraying agents are neutra-
lized.
The spray pipe can be engaged in the receiver on
the pump lever. The nozzle must then be in the hol-
der on the tank base.
Only use original GLORIA spare parts for repairs.
Repairs should only be done by GLORIA service
centres.
Remedy
Tighten up the hose connection.
Check the pressure in the unit with
water
The filter in the quick-acting valve
or else the spray nozzle is blocked
Clean the nozzle
We reserve the right to make technical changes and