Malfunctions; Care And Maintenance - FireWare Cumulus Mode D'emploi Utilisateurs

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

User Manual
EN
FireWare Cumulus
Press the Enterbutton once to start the fogging
process. The machine now produces fog until the
Enter-button is pressed again. The output can be
changed during the fogging process.
6.

Malfunctions

Problems
The fog machine does not fog.
The fog machine fogs uncontrollably
The fog machine switches off suddenly.
Loud droning sound during fogging
E-4 appears on the LED display.
E-1 appears on the LED display
Other.
7.

Care and maintenance

Make sure that the vent holes are not clogged or blocked and keep them free of dust. Check the air
valve/filter regularly and clean or replace it when necessary. If the same fluid is used every time, the
filter should be cleansed thoroughly when another fluid will be used. This to prevent clogging.
18
FireWare Cumulus
Solutions
Check external control signals from DMX or the
remote control
Check mains supply
Check if the fluid tank is filled
Check for correct connections between the
machine and the tank
Check for fluid in the fluid tube
Check if fluid filter is clogged
Check mains supply
Check unit for moisture
The „Temperature cutout" has switched off due
to overheating. Remove external heat source
(for instance projector shining right onto the
housing) and/or make shure sufficient fresh air
supply. After 15 to 30 minutes the unit should
switch back to „on" again.
The pump is running dry. Avoid this absolutely!
Refill fluid bottle
Double check connection fluid tube and fluid
bottle.
The machine is getting too hot. The heating
switches off and the machine cools down.
Solution: Disconnect the machine from the main
supply for a moment and then re-connect it.
Please send the machine to FireWare.
Contact FireWare.