CAUTION
The boiler warranty may be void if: water leaks in the
system are not repaired, the boiler is used as a source
of domestic hot water or a significant amount of new
water or air is introduced into the system.
4.2

PROCEDURE:

1.
Let the boiler cool down;
2.
Close the maintenance valves, which are installed at the
water inlet and outlet of the boiler. N.B.: It is not
recommended to drain the water from the heating pipe
system;
5.0

FURNACE INFORMATION

Model :
Installation date of the electric boiler :
Service Telephone # – Day :
Dealer Name and Address :
3.
Hook-up a garden hose to the drain valve and place it
close to a floor drain;
4.
Open the purge valve until the water comes out clean
and clear;
5.
Close the valve.
It is recommended to perform a visual inspection of the
boiler electrical compartment annually, during the heating
season. The items to check are the water tightness of the
elements, signs of overheating of the electrical components
and the wiring. Corrective measures must be undertaken as
required, as soon as possible.
Defective components should always be replaced with the
Original Equipment Manufacturer's parts.