HYDRUS
Display / symbols
Forward flow
Reverse
flow
Alarm /
fault
Set day
Reverse volume
10.

Displays

Error display (visual indication on the LC display in the event of an error)
Error code Description
C1
Basic parameter error in flash or RAM - Meter must be
replaced
The meter must be replaced.
E1
Temperature measurement error (temp. outside range,
sensor short-circuit, sensor break)
Meter should be checked in the event of sensor short-cir-
cuit or sensor break
E4
Hardware error, faulty ultrasonic transducer or short-cir-
cuit in ultrasonic transducer
Meter should be checked
E5
Too frequent reading (no communication possible for
short time)
E7*
No meaningful ultrasonic signal, air in the measuring path
-22-
Deutsch
English
Button
Calibration
value
Français
Português
Water volume
information
arrow
Flow informa-
tion arrow
Service
value
Test mode
Forward volume