STOVE DIMENSIONS AND CONNECTION MEASUREMENTS
305
360
DISTANCE TO NON COMBUSTIBLE MATERIALS
The stove can be recessed in a suitable sized non - combus�ble fireplace but a permanent free air gap of at
least 50mm must be le� around the sides and top and at least 50mm at the back of the stove to obtain
reasonable heat output and for access to the stove for removal and maintenance. A clearance of 100mm will
give a be�er heat output.
All non - combus�ble walls closer than 100mm to the stove should be at least 75mm thick. For prac�cal reasons
the back wall of the fireplace recess and the hearth should ideally be made of non -combus�ble material. When
installing a your stove in a non combus�ble chamber combus�ble materials should not be located where the
heat dissipa�ng through the walls of fireplaces or flues could ignite it. Therefore when installing the stove in
the presence of combus�ble materials due account must be taken of the guidance on the separa�on of
combus�ble material given in Building Regula�ons Approved Document J and also in these stove instruc�ons.
The minimum distances to flammable materials are specified on the EN 13240 plate on the back of the stove
Loxton 3
Loxton 3 Convector
128
Distance to
Distance to combus�bles rear
combus�bles rear
with flue convector plate fi�ed.
200mm
200mm
combus�bles sides
100mm
100mm
5 of 24
125
380
Distance to
Suitable for 12mm
floor plate
600mm
200mm
YES
YES