- Use the power packs only at 230 V alternating voltage and 50 Hz. It is inadmissible to use them in damp
rooms or outdoors or under detrimental ambient conditions. Detrimental ambient conditions are:
- Moisture of excessively high humidity of air,
- Dust and inflammable gases, vapours or solvents,
- Heavy vibrations
Any use other than the one described above damages the product. Moreover, this involves dangers such as
e.g., short-circuit, fire, electric shock, etc. No part of the product may be modified or rebuilt and the housing
must not be opened. Always observe the safety instructions.

Control elements

Front view (Fold-out page)
1. ON-OFF switch "ON (I) OFF (0)"
2. LED indicator (luminescence diode, briefly light-emitting diode) as an operation indicator.
3. "COARSE" setting knob for a coarse adjustment of "VOLTAGE" (output voltage)
4. "FINE" setting knob for a fine adjustment of output voltage
6. Indicator of output current (to set the current limit)
7. "COARSE" setting knob for a coarse adjustment of the current limit (output current)
8. "FINE" setting knob for a fine adjustment of the current limit
9. "PRESET" switch for a change of the display from the instantaneous load current of the "NORM" con-
suming unit over to the current limit "C-LIMIT" which is set.
10. "OUTPUT" switch to switch the power pack output on (ON) or off (OFF)
11. Yellow-light "OFF" LED to indicate that "Output" is switched off
12. Yellow-light "TEMP" LED to indicate an excess temperature (thermal overload)
13. Green-light "CV" LED as an LED indicator of the output voltage (Constant Voltage)
14. Red-light "CC" LED as an LED indicator of the current limit (Constant Current)
15. Metallic jack, 4 mm, for connection to ground (= protective grounding conductor = direct connection to
the protective conductor of the mains lead)
16. High-load terminal/-4-mm jack for the positive (+) output
17. High-load terminal/-4-mm jack for the negative (+) output
Back page (with no figure)
18. Holder for mains fuse (overcurrent switch for 3635)
19. Appliance coupler for non-heating apparatus to connect the fully insulated mains lead
20. Apertures for cooling with a fan installed behind (forced ventilation)
Table of contents
Introduction ..................................................................................................................................................11
Prescribed use..............................................................................................................................................11
Setting elements (Fold-out page) .................................................................................................................12
Table of contents ..........................................................................................................................................12
Safety instructions ........................................................................................................................................13
Connection, putting into operation, maintenance, exchange of fuses.........................................................14
Disposal ........................................................................................................................................................16
Specifications ...............................................................................................................................................17
12
Specifications and display tolerances
General
Type/Design
3610
Operation voltage
Mains frequency
Max. power input, approx
730 VA
Output voltages (D.C.)
Output current (D.C.)
0,01 – 10 A
Max. (short-time) output current
13A
Rated output wattage (W)
360
Mains fuse (SA= slow-action)
4,0 AT
Load balance at 100%
0,01% + 1mV
Load variation (voltage)
Load balance at 100%
0,1% + 20mA
Load variation (current)
Residual (ripple)
1 mVeff
Weight (approx)
8,3 kg
Dimensions (W x H x L, in mm
483 x 105 x 315

Ambient conditions

Operating temperature :
from +5°C to +40°C at a relative air humidity of max. 85%, non-condensing
Display tolerances
The error of display is quoted in ± (% of read-out + number of digits = dgt(s) ). The validity of display is
applicable to a temperature of +23°C ± 5K at a relative air humidity of less than 85 %, non-condensing. The
warm-up time is 1 minute.
Measuring range
Voltmeter
199.9 V
Amperemeter
199.9 A
3620
3635
230 VAC (+6 / -10%)
50 - 60 Hz
1500 VA
1850 VA
0 – 36 (37,5) V
0,01 – 20 A
0,01 – 35 A
22A
40A
720
1260
8 AT
10 AT
0,03% + 5mV
0,05% + 10mV
0,2% + 30mA
0,2% + 30 mA
2 mVeff
2 mVeff
13,0 kg
20,0 kg
483 x 105 x 394
483 x 145 x 455
Accuracy
Resolution
± (0.5 % +1 dgt)
100 mV (= 0.1 V)
± (1.0 % +1 dgt)
10 mA (=0.01 A)
17