Wha 900 Detail View; Technical Data - Weller WHA 900 Mode D'emploi

Masquer les pouces Voir aussi pour WHA 900:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WHA 900 Detailed View

Technical Data:

Dimensions (L x W x H):
Main voltage:
Power consumption:
Hot air pencil output:
Fuse:
Temperature control:
Temperature Control accuracy:
Flow control:
Noise level:
Arrow.com.
Arrow.com.
Arrow.com.
Downloaded from
Downloaded from
Downloaded from
Step 2
Step 1
210 x 170 x 110 mm (8 3/16"; 6 5/8"; 4 1/4"
120 VAC
750 WATTS
700 WATTS
T 10 AMP
Variable between 50 °C (120 °F) and 1000 °C (1020 °F)
± 30 °C (90 °F)
Variable between 5 - 50 l/min
56dB(A) distance 1m at max. airflow level
1. LED Heater Control
2. VariableTemperature Control; Range 50 °C (120 °F) and
550 °C (1020 °F)
3. Air Flow Control; Range 5 to 50 l/minute
4. Power Switch
5. Push Button Control
6. Hot Air Pencil and Hose Assembly
7. Fuse T 10 A
8. Receptacle 120 VAC
9. Single-stage foot switch (optional)