9.0 Operating Instructions

®
WHISPA III
RCU fan convectors are controlled by the switch on
the front of the unit.
Ensure the electricity supply is switched on.
Heating Mode
The fan will only operate when
The central heating boiler is on
The pump is running
The system water temperature is greater than 110°F.
The room thermostat linked to the unit is switched on.
Ensure boiler is on, and set timer, boiler controls and room
thermostats as necessary.
l Set the fan speed switch to the LOW (I) position.
l The unit will now run on low fan speed. For satisfactory
operation the mean water temperature should not be below
140°F.
Operating Sequence
Power On
Timer On
Boiler On
Pump running
Solenoid valve
Select fan speed
energises and valve
Turn up room
opens
thermostat
(1-2 seconds)
®
WHISPA III
5000, 9000 & 12000 RCU
Temperature Control
The room thermostat setting should be adjusted to obtain the
desired temperature.
The fan speed can be set to boost by switching the fan speed
switch to II.
A low speed setting is recommended for normal operation with
the higher speeds for boost heating when required.
Low Limit Operation
The low limit thermostat fitted to the WHISPA III
ensure that the fan stops after the heating system is switched
off and the water flow stops. If left in an operating position the
unit will automatically restart when the heating system is
reheated.
Off Position
Set the fan speed selector switch to the off position.
Warm water flows
into coil. After 1-2
mins low limit stat
makes as coil
temperature rises
and fan starts.
09
®
RCU will
Unit cycles on room
thermostat through
similar sequence
while heating is on.