ACT™ Conversion

Enabling ACT™

To enable ACT™:
1. Before hood installation, gain access to PC board by removing filters, side panels (if applicable),
and light panel.
2. Change plastic jumper positioning as shown in FIG. H to set the desired maximum blower CFM.
3. Re-install PC board and continue with hood installation.
4. Remove the appropriate foil CFM sticker included with the hood literature and place inside the
hood body below the wiring diagram or in another clearly visible location.
To verify if your installer enabled ACT™:
1. With hood off, press and hold the power button for three seconds. If all speed level indicators
illuminate = default max. CFM, if speed 1 & 2 level indicators illuminate = 390 max. CFM, if speed 1
level indicator illuminate = 290 max. CFM
2. When ACT™ is enabled, the number of blower speeds will be reduced.
390 CFM = max. 2 speeds and 290 CFM = max. 1 speed.
3. There should also be a foil label located inside the hood body near the wiring diagram that
indicates the blower CFM.
22
7
8
7
5
6
3
4
1
2
5
3
1
J u m p e r 3 - 4
Max. Blower CFM
PC Board
FIG. H
Monsoon Mini II Use, Care, and Installation Guide
Jumper Pins
Plastic
7
8
Jumper
5
6
3
4
1
2
J u m p e r 5 - 6 or 7-8
DEFAULT POSITION
Default Max. Blower CFM
8
7
6
5
4
3
2
1
J u m p e r 1 - 2
Max. Blower CFM
390
290
C O R E
M O N S O O N M I N I I I
I N S E R T
8
6
4
2