HT EASYTEST Guide Rapide D'utilisation page 23

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 52
DC Current with transducer clamp (In1 input – STD clamp)
Range [mV]
-1999.9  -1.0
1.0  1999.9
Values lower to ±1mVDC are zeroed
AC TRMS Current with transducer clamp (In1 input – STD clamp)
Range [mV]
1.0  2999.9
Values lower to 1mVAC are zeroed ; Max crest factor: 3
DC/AC TRMS current with transducer clamp (In1 input – STD clamp)
FS clamp / Output ratio
1A/1V AC
5A/1V AC
10A/1V AC/DC
30A/3V AC
40A/400mV AC/DC
100A/1V AC/DC
200A/1V AC
300A/3V AC
400A/400mV AC/DC
1000A/1V AC/DC
2000A/1V AC
3000A/3V AC
Resolution [mV]
0.1
Frequency [Hz]
50/60Hz ±5%
Measurement range
0.1mA ÷ 999.9mA AC
0.001A ÷ 4.999A AC
0.001A ÷ 9.999A AC/DC
0.01A ÷ 29.99A AC
0.01A ÷ 39.99A AC/DC
0.01A ÷ 99.99A AC/DC
0.01A ÷ 199.99A AC
0.01A ÷ 299.99A AC
0.1A ÷ 399.9A AC/DC
0.1A ÷ 999.9A AC/DC
0.1A ÷ 1999.9A AC
0.1A ÷ 2999.9A AC
EN - 8
EASYTEST-COMBI519-COMBI521
Resolution [mV]
0.1
Quick reference guide
Accuracy
(5.0%rdg + 2dgt)
Accuracy
(5.0%rdg + 2dgt)
Resolution
0.1mA AC
0.001A AC
0.001A AC/DC
0.01A AC
0.01A AC/DC
0.01A AC/DC
0.01A AC
0.01A AC
0.1A AC/DC
0.1A AC/DC
0.1A AC
0.1A AC