Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

+
! "#$ %& '( )
*
*
Connect the cables with wire terminating sleeves directly to the
circuit breaker.
4
Only for the MES 250-2/4 and MES 400-2/4: Cross cable section:
2.5 mm² Connection for air-conditioning equipment. Connect the
cable without wire terminating sleeves to the cage tension spring
clamp. Green/yellow = protective earth (PE).
5
Connection for 230 Volt electrical equipment: conductor cross sec-
tion 1.5 mm² to 2.5 mm². Connect the cables without wire terminat-
ing sleeves to the cage tension spring clamps. Green/yellow = protec-
tive earth (PE).
6
Cable connection strip suitable for:
2x 4 mm² conductor cross section
2x 2.5 mm² conductor cross section
1x 1.5 mm² conductor cross section
6x 1.5 mm² conductor cross-section
Check that all the connections are firm and secure. Connect the mains cable to
the power distribution of your caravan. Connect the green/yellow cable to the
earth circuit!

Commissioning

The MES begins operation as soon as it is connected to the mains (mains op-
eration) or to the vehicle battery in the towing vehicle (driving operation).
Mains operation on ferries
The voltage of the mains power provided on ferries can be subject to wide
variations. Do not, therefore, connect the device to this supply.
Generator operation
Please observe the methods of handling prescribed in the manufacturer's oper-
ating instructions. The generator must operate within the parameters for a 230
V mains supply. Do not connect the device to the generator until it is running
steady, and disconnect it before you switch it off. The voltage spikes created
during the start-up and shut-down phases may damage the device.
Lerchenfeldstr. 9 87600 Kaufbeuren Tel.: +49(0)8341 / 9764-0 Fax: +49(0)8341 / 67806
! '$$ %& '(
*
)
For potential equalisation
for circuit breaker and air-
conditioning equipment
for circuit breaker
for 230 Volt electrical equip-
ment
33

Publicité

Table des Matières
loading

Table des Matières