Regarding use:
•
•
•
•
•
•
Regarding testing of the hydraulic hoses:
•
•
•
2. Specifications
p
rel:
Q:
T:
Overload pressure:
Bursting pressure:
Maximum pressure/
bypass opening pressure:
Operating conditions:
Fluid temperature:
Storage conditions:
Protection class:
Power supply:
Fuse:
Hydraulic unit dimensions
L x W x H:
Display dimensions
L x W x H:
Hydraulic unit weight:
Display weight:
The hydraulic hoses are NOT suitable for permanent use.
The area of application is restricted to brief measurements for diagnostic purposes.
For permanent use, ONLY rigid hydraulic lines (not included in the scope of delivery) are
permitted.
It must be ensured that the unit is always in an oil drip pan when it is operated
No technical modifications to the unit may be made.
Failure to comply with these safety notes may result in damage to the unit and injuries to
the operator.
Check for mechanical damage prior to every use. In the event of damage, the hydraulic
hoses must no longer be used. Damaged hydraulic hoses must be replaced.
The hydraulic hoses are to be checked at regular intervals.
Non-specified use of the product or failure to observe the safety and operating notes may
lead to severe malfunctions as well as personal injury and property damage. In particu-
lar, improper installation of the testing unit and the corresponding adapter and hydraulic
hoses may result in the testing unit breaking off or rupturing of the hydraulic hoses.
HPGD 1000_LR_01
041902_1
7,5...75 l/min
± 2,0 % of m.v.**
38 cm x 16 cm x 21 cm
ca. 3700 g
HPGD 1000_LR_03
041904_1
0...250 bar ±0,5 % FS*
15...300 l/min
± 2,0 % of m.v.**
0...125 °C ± 2 % FS*
250 bar
1000 bar
155 bar
-25°...55 °C RH 60 %
max. 80 °C
-25...60 °C RH 75 %
IP 44 according to EN 60529
12...24 VDC
MT1A250VAC (2 pcs.)
50 cm x 19 cm x 23 cm
20 cm x 15 cm x 18 cm
ca. 7200 g
ca. 2100 g
- 7 -
HPGD 1000_LR_02
041903_1
40...600 l/min
± 2,0 % of m.v.**
53 cm x 19 cm x 23 cm
ca. 7900 g
*full scale / ** of measured value