6. Installing the Filter Housings and Cartridges
A) Locate two black rubber O-rings and silicone grease in plastic
bag .
B) Lubricate each O-ring with a coating of clean silicone grease .
With two fingers, press each O-ring securely into the groove
below the threads of each housing .
CAUTION:
The rubber O-ring provides the water-tight seal between
the cap and the bottom of the housing . It is improtant that the O-ring
be properly seated in the groove below the threads of the housing or
a water leak could occur .
C) Unwrap cartridges and insert in the bottom of the housings .
Make sure cartridge slips over standpipe in the bottom of the
housing .
NOTE: Be sure to install cartridges in proper housings (see Figure 10) .
D) Screw housings onto unit and HAND TIGHTEN ONLY . Do not
over-tighten . Do not use the wrench or other mechanical devices .
The wrench that is provided in the package is only to loosen the
housing when it is time to change the cartridges .
CB1
2nd Stage Postfilter
Figure 10
• 6 •
R200
4th Stage Postfilter
OM1 Membrane
3rd Stage Postfilter
RS14
1st Stage Postfilter
7. Connecting the Faucet to the Drain
NOTE: This is a gravity drain line . Any loops, kinks or sharp bends
must be eliminated before proceeding . Failure to create a straight
line to the drain may result in reject water leaking through the air gap
in the faucet onto the counter top and below the faucet .
A) Align the 3/8" red tubing from the faucet with the compression
nut on the drain clamp . Create as straight a path as possible with
the tubing . Cut the tubing squarely below the nut and remove the
internal and external burrs .
B) Loosen the compression nut two complete turns . Insert the tubing
into the nut until it stops. Tighten with fingers, then tighten 1 to 2
turns with a wrench .
A
Figure 11
8. Installation of Mounting Screws
A) If system is being installed under the kitchen sink, locate it
on back or right wall . Make sure to allow ample space for
installation (Figure 12). To change the filter cartridges, a minimum
of 1-1/2" of clearance is required underneath the filter housings.
A minimum of 2" of clearance from the left side of the unit is also
required or 5" from the left bracket mounting screw hole .
B) Install mounting screws at least 15" from cabinet floor and 7-1/2"
apart . Leave a 5/16" space between the head of the screw and
the wall to slip bracket onto screws .
NOTE: Each connection fitting on the RO Assembly has a plug that
must be removed before inserting tubing . Push in on the collar and
pull the plug out .
5" (min .)
2" (min .)
Figure 12
3/8" Tube