3. Light the appliance and turn the control to full input.
4. Adjust the pressure adjustment screw using a small
jeweller's size fl at blade screwdriver—as shown
below—while the appliance is running at full input to
produce manifold pressure, as per Specifi cations on
page 1.
Front Face of Control Valve
Pry off
Plastic Cap
5. Turn off the appliance, remove the manometer and
tighten the test tapping screw.
6. Check all connections for leaks.
Reinstall fuel bed
To reinstall the fuel bed—see the installation
instructions supplied with the appliance.
Adjust air shutter
Adjust the air shutter to desired position after manifold
pressure is set and fuel bed reinstalled. The air shutter
is linked to a lever located under the fi rebox. To adjust
the air shutter:
1. Locate the aeration lever and the wing nut under the
fi rebox left of the valve.
2. Loosen the lever's wing nut. Do not remove the
wing nut!
3. Move the lever left or right to the desired position.
4. Tighten the wing nut.
Air shutter
Air shutter
slider
Aeration
lever
Open
Close
4
Front Face of
Control Valve
Pressure
adjustment
screw behind
plastic cap
Increases pressure
Decreases pressure
Wing nut
under lever
Fit the specifi cations label
1. Complete the required details of label "This
appliance was converted on... by..." position along
with the label "This control has been converted...".
2. Fit the labels on the bottom fl oor of the appliance
as close as possible to the data card located on the
right side of the fi rebox.
THIS APPLIANCE (MODEL 785J) HAS
BEEN CONVERTED TO PROPANE GAS
ORIFICES: BURNER #360
PILOT # 30
785JLN
SUPPLY PRESSURE 11" MIN 14" MAX
FOR NATURAL GAS POUR LE GAZ NATUREL
MANIFOLD PRESSURE 9" W.C.
INPUT 30,000Btu/h MAX
KIT # 785PGKV2
CET APPAREIL (MODELE 785J) A ETE
CONVERTI AU GAZ PROPANE.
INJECTEURS BRULEUR # 360
785N10898
VEILLEUSE #30
PRESSION D'ADMISSION 11" MIN 14"
MAX. PRESSION A TUBULURE
D'ALIMENTATION 9" COL. D'EAU
DEBIT CALORIFIQUE 30,000Btu/h.
TROUSSE #785PGKV2
4004564/01
CIRCULATING FAN KIT 795CFK
VENTILATEUR POUR CIR
CULATION D'AIR 795CFK
120V, 60Hz, LESS THAN 1A
120V, 60Hz, MOINS DE 1A
785PGKV2 CONVERSION KIT TO
785PGKV2 KIT DE CONVERSION AU
PROPANE
GAZ PROPANE
4004281/04
4003371-790/791/792/798
Because our policy is one of constant development and
improvement, details may vary slightly from those given
in this publication.
Designed and Manufactured by / for Miles Industries Ltd.
190–2255 Dollarton Highway,
North Vancouver, BC, CANADA V7H 3B1
Tel. 604-984-3496 Fax 604-984-0246
www.valorfi replaces.com
© Copyright Miles Industries Ltd., 2018
Data plate

Publicité

loading

Ce manuel est également adapté pour:

H6 1400kngkH6 1400kpgk