Replace the burner
1. To reinstall the burner, fi t the burner in the fi rebox
inserting the front tabs fi rst in the lances.
Screw
Note: Ensure that the
front of the burner is
well hooked when re-
installing!
Again, be careful not
to hook the pilot hood
when fi tting the burner
over the pilot.
2. Fix the burner to the manifold bracket at the rear
with screw.
3. Replace ceramic liner panels.
Set the manifold pressure
1. Fit a manometer to the manifold pressure test tap
on the valve—see fi gure below.
Loosen screw to check
(tighten afterwards)
Valve Inlet
Pressure
Manifold
Pressure
Pressure Test Tappings
2. Light the appliance and turn the control to full input.
Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication.
4
Test Tap
Designed and Manufactured by / for
Miles Industries Ltd.
190–2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1
Tel. 604-984-3496 Fax 604-984-0246
www.valorfi replaces.com
3. Adjust the pressure adjustment screw using a small
jeweller's size fl at blade screwdriver—as shown
below—while the appliance is running at full input
to produce manifold pressure, as per Specifi cations
table on page 1.
Front Face of
Control Valve
Pry off
plastic cap
4. Turn off the appliance, remove the manometer and
tighten the test tapping screw.
5. Check all connections for leaks.
Reinstall the fuel bed
To reinstall the fuel bed to the installation of the
fi replace, see the installation instructions supplied with
the appliance.
Fit the specifi cations label
1. Complete the required details of label "This
appliance was converted on... by..." position along
with the label "This control has been converted...".
2. Fit the labels on
the bottom fl oor of
the appliance as
close as possible
to the data card
rolled up and fi xed
to the bottom of
fi replace behind
the valve cover
panel.
BEEN CONVERTED TO PROPANE GAS
ORIFICES: BURNER #360
PILOT # 30
SUPPLY PRESSURE 11" MIN 14" MAX
MANIFOLD PRESSURE 9" W.C.
INPUT 30,000Btu/h MAX
KIT # 785PGKV2
CET APPAREIL (MODELE 785J) A ETE
CONVERTI AU GAZ PROPANE.
INJECTEURS BRULEUR # 360
VEILLEUSE #30
PRESSION D'ADMISSION 11" MIN 14"
MAX. PRESSION A TUBULURE
D'ALIMENTATION 9" COL. D'EAU
DEBIT CALORIFIQUE 30,000Btu/h.
TROUSSE #785PGKV2
© Copyright Miles Industries Ltd., 2015
Front Face of
Control Valve
Pressure
adjustment
screw behind
plastic cap
Increases pressure
Decreases pressure
4004564/01
Data plate