TECHNICAL SPECIFICATIONS – GAS DRYER
220-240V~50Hz 1ph 12A max. IP24 Clothes capacity: 9.0 kg max. each dryer. Sound pressure level,
Lpa: 58 dBA (uncertainty, Kpa: +/–10 dBA) Total mass: 135 kg max.
Factory set for NATURAL GAS: Injector size: 2.2 mm Heat input gross: 5.9 kW
European Country:
European Gas Category:
Gas Flow Rate:
Supply Pressure (G20):
Factory Adjusted Pressure:
With LP Gas Conversion Kit: Injector size: 1.25 mm Heat input gross: 6.4 kW
European Country:
European Gas Category:
Butane Supply Pressure (G30):
Adjusted Pressure:
Propane Supply Pressure (G31):
Adjusted Pressure:
With France/Belgium NATURAL GAS conversion kit: Injector size: 1.65 mm Heat input gross: 5.9 kW
European Country:
European Gas Category:
Supply Pressure (G20):
Supply Pressure (G25):
Adjusted Pressure:
NOTE: Conversion kit: From Natural Gas to LP Gas: Whirlpool Part No. W10233219.
Conversion kit: From Natural Gas to Natural Gas - France/Belgium: Whirlpool Part No. W10181947.
Manufacturer: Whirlpool Corporation, Benton Harbor, Michigan 49022, U.S.A.
Manufacturing Site: Whirlpool Corporation, 1300 Marion-Agosta Rd., Marion, OH 43302, U.S.A.
EU representatives: Maytag UK Ltd., 2 St. Annes Blvd., Redhill, RH1 1AX, UK
& Bauknecht Hausgeräte GmbH, D-73614 Schorndorf, Germany
All manuals and user guides at all-guides.com
CH, CZ, CY, ES, GB, GR, HR,
IE, IT, PT, SI, SK, TR
II 2H3+
0.562703 m
20 mbar
7.4 mbar
CH, CZ, CY, ES, GB, GR, HR,
IE, IT, PT, SI, SK, TR
II 2H3+
28-30 mbar
N/A
37 mbar
N/A
EU - DECLARATION OF CONFORMITY
CE - DECLARATION DE CONFORMITE
BAUKNECHT HAUSGERÄTE GmbH, D-73614 Schorndorf
WE (nous):
WHIRLPOOL EUROPE S.r.l I-21025 COMERIO
representing (représentant):
declare under our sole responsibility that the product
déclarons sous notre propre responsabilité que le produit
Maytag
dryer
(sèche-linge) :
Maytag
to which this declaration relates is in conformity with the following standard(s) or other
normative document(s)
auquel se référe cette déclaration est conforme aux normes suivantes ou autres documents normatifs
EN 60335-1:2002+A1+A2+A11+A12+A13
EN 60335-2-11:2003+A1+A2
EN 12752-1:1999
EN 62233:2008
EN ISO 10472-1:2008
EN ISO 10472-4:2008
EN 55014-1:2006
EN 55014-2:1995+A1:2001
EN 61000-3-12:2005
EN 61000-3-11:2000
following the provisions of Directive(s):
suivant les prévisions des Directives :
2009/142/EC EUROPEAN GAS APPLIANCE DIRECTIVE
2006/95/EC LOW VOLTAGE DIRECTIVE
2004/108/EC ELECTROMAGNETIC COMPATIBILITY DIRECTIVE
Electro-magnétique)
2006/42/EC MACHINERY DIRECTIVE
Schorndorf, 29.04.2010
Place and date:
lieu et date :
CY, CZ, DK, EE, FI, GR, HU, IT,
3
/hr
CY, CZ, DK, EE, FI, GR, HU, IT,
FR, BE
I 2E+
20 mbar
25 mbar
N/A
MLG24PD
MLG24PN
(CEE Directive Basse Tension)
(CEE Directive Compatibilité
represented by
Roberto Mottura
Director PDC, FC
Name and signature of authorised person
Nom et signature de la personne autorisée
NO, RO, SE, SK, TR
II 2H3B/P
3
/hr
0.562703 m
20 mbar
7.4 mbar
NO, RO, SE, SK, TR
II 2H3B/P
30 mbar
N/A
30 mbar
N/A
11