IMPORTANT: Observeallgoverningcodesandordinances.
Thisdryerissuppliedwithoutanelectriccordandplug.Itmust
beconnectedbyacompetentelectriciantoasingle-phase
electricitysupplyatthevoltageshownonthedataplate,using
asuitablefixedwiringinstallationinaccordancewithlocaland
nationalwiringregulations.
A3-wirecircularcordofminimumconductorsize2.5mm
■
cross-sectionareashouldbeused.
A30Asupplyfuseshouldbeused,andaswitchhaving
■
acontactseparationinbothpolesthatprovidesfull
disconnectionunderover-voltagecategoryIIIconditions
mustbeincorporatedintothefixedwiringinaccordance
withlocalwiringregulations.Thedryershouldbe
positionedsothatthedisconnectionswitchisclearlyvisible
andeasilyaccessibletotheuser.Thisdisconnectionswitch
alsoprovidesthefunctionofanemergencystopcontrolfor
the user.
Acordclampbushisprovidedonthedryer,andshouldbe
■
tightenedoncompletionofwiring.Theelectricalmains
terminalsarelocatedbehindthesmallrearaccesspanel
(terminalblockcover),andconnectionsshouldbemade
inaccordancewiththeterminalmarkings.Rememberto
replacetheterminalaccesspanel(terminalblockcover).
Ifthesupplycordisdamaged,itmustbereplacedwitha
speciallyterminatedcordbyanauthorizedserviceagent
orasimilarlycompetentpersoninordertoavoidahazard.
Donotuseanadapter.
Donotuseanextensioncord.
NOTE:InaccordancewiththeEuropeanEMCDirective
(2004/108/EC),themaximumelectricitysupplysystem
impedancetowhichtheelectricdryershouldbeconnected
isdeclaredtobe0.054Ohm+j0.034Ohm.
NOTE:Electricalsafetystandards:Themanufacturerhas
chosencompliancewithIEC/EN.60335standardsasthemost
appropriateforthisdryer.
All manuals and user guides at all-guides.com
2
ELECTRICAL REQUIREMENTS
Ifcodespermitandanadditionalearthbondwireisused,itis
recommendedthataqualifiedelectriciandeterminethatthe
earthbondpathisadequate.
AUSTRALIA ONLY
ForAustralia,eachsingleelectricdryerisfittedwithacord
andplug,withconductorsof2.5mm
andshouldbepluggedintoasuitableelectricalsocketatthe
voltageshownonthedataplate.Donotuseextensionlead
assembliesoncommercialinstallations.Ifthesupplycord
isdamaged,itmustbereplacedwithaspeciallyterminated
cordbyanauthorizedserviceagentorasimilarlyqualified
personinordertoavoidahazard.Eachelectricdryerforother
countriesissuppliedwithoutanelectriccordandplug.
Recommended Earthing Method
WARNING
Electric Shock Hazard
This dryer must be earthed.
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electric shock.
Itisyourresponsibilitytocontactaqualifiedelectrical
■
installertoensurethattheelectricalinstallationis
adequate and in conformance with all local codes
and ordinances.
crosssectionalarea,
2
9