Control buttons on the table fan and the IR remote control
Button "
"
Switching the table fan on/off
Button "
"
Setting/switching off the timer (continuous operation)
Button "
"
Switching the oscillation (swivel mechanism) on/off
Button "
"
Selecting fan speed 1, 2 or 3
Button "
"
Selecting fan turbo speed
Inserting battery into the IR remote control,
change of battery
In general, it is possible to operate the IR remote control with re-
chargeable batteries.
Due to the lower voltage of rechargeable batteries (batteries = 1.5 V,
rechargeable batteries = 1.2 V), the operating time can be shorter.
If you want to use rechargeable batteries despite these limitations,
we recommend the use of NiMH batteries with low self-discharge.
• Open the battery compartment, remove the battery compartment lid.
• Insert two Micro/AAA batteries, with the correct polarity (pay attention
to +/Plus and -/Minus), see the signs in the battery compartment.
• Close the battery compartment again.
• The battery needs replacing if the range between the IR remote control
and the table fan decreases or the table fan no longer reacts to the IR
remote control.
Start-up
• Place the table fan on a level, firm and sufficiently large area. Protect
valuable furniture surfaces by using a suitable mat to prevent scratch-
es, pressure points or discolourations.
• Connect the power plug to a standard protected ground mains socket.
Operation
The table fan can be operated with the control buttons on the top of
the fan or with the IR remote control enclosed.
The labelling of the buttons is the same on the table fan and on the
IR remote control.
a) Switching on/off
Briefly press the "
" button to switch the table fan on or off. When the
table fan is switched on, it always runs with fan speed "3" .
b) Selecting the fan speed
By pressing the "
" button briefly several times, you can select the
different fan speeds (1, 2 or 3). Depending on the fan speed, the corre-
sponding symbol (G) in the display shows one, two or three rotor blades.
c) Selecting turbo speed
Briefly press the "
" button to activate or deactivate the full power
of the table fan.
d) Setting the timer
Briefly press the "
" button several times to set the timer. The function
is shown in the display:
Display "FU"
Continuous operation (timer switched off)
Display "1" .... "10"
The table fan switches off automatically after
1....10 hours
e) Oscillation on/off
The oscillation (swivel mechanism) can be switched on or off with the
"
" button.
The fan housing can also be swivelled to the left and right by hand
to adjust the direction of the flow. It is not necessary to laboriously
re-position the table fan or to use the oscillation function.
Do not apply force when swivelling the fan housing! The mechanical
system has an end stop. Do not overwind the fan housing it!
All manuals and user guides at all-guides.com
Maintenance and cleaning
• The product does not require maintenance. The product contains no
• Switch off the table fan and disconnect it from the mains voltage be-
• To clean the outside of the product, a dry, soft and clean cloth is suffi-
• Dust can be easily removed using a clean, soft and long-bristled brush
Disposal
a) General
b) Batteries and rechargeable batteries
As the end user, you are required by law (battery ordinance) to return all
used batteries and rechargeable batteries; it is not permitted to dispose
of batteries with normal household waste.
Used batteries, rechargeable batteries and coin cells can be returned to
collection points in your municipality, our stores or wherever batteries /
rechargeable batteries / coin cells are sold.
You thereby fulfil your statutory obligations and contribute to the protec-
tion of the environment.
Technical data
a) Table fan
Operating voltage .........................220 - 240 V/AC, 50/60 Hz
Power consumption ......................max. 50 W
Protection class ..............................I
Cable length ...................................approx. 1.8 m
Speed steps ....................................4 (3 + turbo)
Airflow ............................................max. 3486 m³/h
Noise ...............................................max. 47 dB
Oscillation (panning function) ......yes (90°), can be switched on/off
Timer ..............................................yes (1, 2, 3,........, 10 hours)
Ambient conditions ....................... temperature 0 °C to +45 °C, air humid-
Rotor diameter ...............................280 mm
Rotor blades ...................................6
Dimensions (W x H x D) ................440 x 500 x 200 mm
.........................................................
Weight .............................................approx. 4.5 kg
b) IR remote control
Power supply ................................. 2x batteries of type AAA/Micro
parts that require servicing. Therefore, do not open it.
Maintenance or repairs may only be performed by qualified personnel
or a specialised repair shop.
fore cleaning. Switch the table fan off and pull out the mains plug from
the protected ground mains socket.
cient.
and a vacuum cleaner. Alternatively, you can also use a compressed air
spray to remove dust from the rotor blades.
Do not use abrasive cleaning agents, cleaning alcohol or other chem-
ical solutions since these could damage the housing or even impair
operation.
The product must not be disposed of with the household waste.
Please dispose of the product, when it is no longer of use, ac-
cording to the current statutory requirements.
Remove any batteries/rechargeable batteries inserted in the IR
remote control and dispose of them separately from the product.
Batteries / rechargeable batteries containing hazardous sub-
stances are labelled with this symbol to indicate that disposal
in domestic waste is prohibited. The designations for the heavy
metals involved are: Cd = cadmium, Hg = mercury, Pb = lead.
Legal notice
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the
capture in electronic data processing systems require the prior written approval by the editor. Reprinting, also
in part, is prohibited. This publication represent the technical status at the time of printing.
© Copyright 2016 by Conrad Electronic SE.
ity 0% to 85% relative, not condensing
(max. depth 375 mm when fan hous-
ing is swivelled)