FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
• 50M56U-751 Integrated Furnace Control
• 9-Pin Adapter Harness
• Flip Adapter Harness
50M56U-751 is an aftermarket direct replacement
control kit for Carrier and ICP single stage furnace
products with PSC blower motors.
ELECTRICAL RATINGS:
Input Low Voltage: 24 VAC, 60 Hz
Input Line Voltage: 120 VAC, 60 Hz, 1φ
Max Input Current: 0.45 A @ 24 VAC
Relay Contact Ratings:
Gas Valve: 1.5 A, 0.6 PF @ 24 VAC
Ignitor Relay: 1.2 A @ 120 VAC
Inducer Relay: 2.8 A @ 120 VAC
Circulator Relay: 10 FLA, 25 LRA @ 120 VAC
Humidifier Load: 1.0 A @ 24 or 120 VAC
Electronic Air Cleaner: 1.0 A @ 120 VAC
Flame Current Requirements:
Minimum current to ensure flame detection:
0.25 μA DC*
Maximum current for non-detection: 0.1 μA DC
Maximum allowable leakage resistance: 100 M
ohms
* Measured with a DC ammeter
Flame Establishing Time: 0.8 seconds maximum
Flame Failure Response Time:
2.0 seconds maximum
OPERATING TEMPERATURE RANGE:
-40° to 176°F (-40° to 80°C)
HUMIDITY RANGE:
5 to 95% relative humidity (non-condensing)
50M56U-751 with Black Cover
INSTALLATION INSTRUCTIONS
emerson.com/white-rodgers
Carrier/ICP Integrated Single Stage
120V Hot Surface Ignition Control Kit
• 4 – 1" Sheet Metal Screws
• 3 – 1/2" Sheet Metal Screws
• Installation Instructions
TWINNING: 50M56U-751 can be twinned. The other
control must also be a 50M56U-751 with Black
cover to ensure proper functionality.
SPECIFICATIONS & TIMINGS
AGENCY APPROVALS:
GASES APPROVED:
Natural, Manufactured, Mixed, Liq-
uid Petroleum, and LP Gas Air Mixtures.
Risk of Electric Shock.
Disconnect electric power
to system until installation
is complete. Do not use on
circuit exceeding specified
voltage. Higher voltage will
damage control and could
cause shock or fire hazard.
This control is not intended
for use in locations where
it may come in contact with
water.
May cause flame rollout.
Shut off main gas to
heating
installation is complete.
PARTS INCLUDED
DESCRIPTION
UL USA / Canada
system
until
PART NO. 37-7751001
2031

Publicité

loading

Sommaire des Matières pour Emerson White-Rodgers 50M56U-751

  • Page 1 2.0 seconds maximum May cause flame rollout. OPERATING TEMPERATURE RANGE: Shut off main gas to -40° to 176°F (-40° to 80°C) heating system until HUMIDITY RANGE: installation is complete. 5 to 95% relative humidity (non-condensing) PART NO. 37-7751001 emerson.com/white-rodgers 2031...
  • Page 2 Furnace 9-Pin 11-Pin NOTE: Furnaces previously serviced with Carrier 325878-751, ICM 282A, or White-Rodgers 50M56U-751 kits may have an adapter harness already installed between the factory wiring and the control being replaced. If found, remove the old adapter harness and replace it with the new one provided in the kit.
  • Page 3 INSTALLATION NOTE: All wiring should be installed according to local 5. Connect all the wires back onto the 50M56U-751 and national electrical codes and ordinances. control board referencing the Wiring Diagram section as needed. 1. Disconnect electrical power and shut off gas supply 6.
  • Page 4 CONFIGURATION Heat ON Delay (sec.) Constant Fan Speed Heat OFF Delay (sec.) SW1-1 SW1-2 SW1- 3 & 4 HEAT* 120* *Default Cool Off Delay Setting The default cool off delay is 90 seconds. If dehumidification control via the thermostat is not desired, the cool off delay can be changed to 5 seconds by placing a jumper between the Y/Y2 and DHUM thermostat inputs.
  • Page 5 WIRING DIAGRAM LEGEND BVSS Blocked Vent Shutoff Switch, Manual-reset, SPST -(N.C.) Dra Safeguard Switch HUMIDIFIER FRS1,2 Flame Rollout Switch - Manual Reset, SPST-(N.C.) 24VAC Housing Pressure Switch, SPST-(N.O.) 11 PIN FUNCTIONS LGPS Low Gas Pressure Switch, SPST-(N.O.) THERMOSTAT # DESCRIPTION Pressure Switch, SPST-(N.O.) FLAME SENSOR LS1,2...
  • Page 6 OPERATION HEAT MODE Output 15 s 5-21 s 2.8 s 25, *60 s 15 s 90, *120, 150, 180 s Thermostat - W Inducer Pressure Switch Ignitor Gas Valve Flame Sensor Blower (Heat Speed) Humidifier (24V) Humidifier (120V) Amber LED - 42 Flash Green LED –...
  • Page 7 TROUBLESHOOTING Green LED Flash Amber LED Flash Red LED Flash Error / Condition Up to 5 Flash Codes Stored in Memory (Auto-Erased After 14 Days) Limit / Roll-Out Lockout Ignition Lockout - After 3 Retries Ignition Lockout - After 10 Recycles Ignitor Failure - Replace Ignitor Gas Heating Lockout Abnormal Flame Proving Signal...
  • Page 8 TECHNICAL SUPPORT: 1-888-725-9797 Emerson and White-Rodgers are trademarks of Emerson Electric Co. ©2020 Emerson Electric Co. emerson.com/white-rodgers All rights reserved.
  • Page 9 PLAGE DE TEMPÉRATURES DE MARCHE : flamme. Coupez l’alimentation de gaz principale au système -40° à 176 °F (-40° à 80 °C) chauffage jusqu’à PLAGE D’HUMIDITÉ : l’installation soit terminée. 5 à 95 % d’humidité relative (sans condensation) DE PIÈCE 37-7751001 emerson.com/white-rodgers 2031...
  • Page 10 CÂBLAGE L’entretien de la plupart des fournaises se fait par le simple branchement direct du câblage d’origine à la nouvelle commande 50M56U-751. Les exceptions à cette règle sont données ci-dessous : Faisceau de câbles adaptateur à 9 broches Utilisé pour le remplacement des commandes d’origine ci-dessous : HK42FZ004, HK42FZ007, HK42FZ008, HK42FZ009, HK42FZ011, HK42FZ016 Neutres du panneau de...
  • Page 11 INSTALLATION REMARQUE : Tout le câblage doit être installé conformément 5. Branchez tous les fils noirs sur le panneau de aux codes et ordonnances locaux et nationaux de l’électricité. commande 50M56U-751 en vous reportant à la section Schéma de câblage, au besoin. 1.
  • Page 12 CONFIGURATION Délai de mise en marche du Vitesse continue du ventilateur Délai d’arrêt du chauffage (s) chauffage (s) SW1-1 SW1-2 SW1-3 ET 4 CHAU.* MARCHE ARRÊT ARRÊT ARRÊT ARRÊT MARCHE MARCHE MARCHE 120* VENT. ARRÊT MARCHE ARRÊT ARRÊT MARCHE ARRÊT MARCHE MARCHE * Par défaut...
  • Page 13 SCHÉMA DE CÂBLAGE LÉGENDE BVSS Contacteur d’évent obstrué - réarmement manuel, UPUD - (N. F.) Contacteur de protec�on de �rage HUMIDIFICATEUR FRS1,2 Limiteur de débordement de flamme - réarmement manuel, UPUD - (N. F.) FONCTIONS CONNECTEUR 24 V C.A. Pressostat boî�er, UPUD - (N. O.) À...
  • Page 14 FONCTIONNEMENT MODE CHAUFFAGE Sortie 15 s 5-21 s 2,8 s 25, *60 s 15 s 90, *120, 150, 180 s Thermostat – W Inducteur Pressostat Allumeur Vanne à gaz Capteur de flamme Ventilateur (vitesse chauffage) Humidificateur (24 V) Humidificateur (120 V) DEL verte –...
  • Page 15 DÉPANNAGE DEL ambrée DEL rouge DEL verte clignotante Erreur/Condition clignotante clignotante Jusqu’à 5 codes de clignotement mémorisés (suppression automatique après 14 jours) Verrouillage de l’interrupteur de fin de course/débordement Verrouillage de l’allumage – Après 3 tentatives Verrouillage de l’allumage – Après 10 cycles successifs Défaillance de l’allumage –...
  • Page 16 SOUTIEN TECHNIQUE : 1 888 725-9797 Emerson et White-Rodgers sont des marques de commerce d’Emerson Electric Co. © 2020 Emerson Electric Co. emerson.com/white-rodgers Tous droits réservés.