FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS MODULE COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
The 50M56-820 is an Integrated Furnace Control for aftermarket
service of Trane Single-Stage furnace products with PSC blower
motor. The kit includes a 120V Silicon Nitride Igniter and can
service systems with both 80V and 120V HSI Ignition.
The kit also includes a cover to replace both covered and
non-covered controls.
ELECTRICAL RATINGS [@ 77°F (25°C)]:
Input Voltage: 25 VAC 50/60 Hz
Max. Input Current @ 30 VAC: 500 mA
Relay Load Ratings:
Valve Relay: 1.5 A @ 25 VAC 60 Hz 0.6 pf
Ignitor Relay: 6.0 A @ 120 VAC 60 Hz (resistive)
Inducer Relay: 2.8 FLA–3.5 LRA @ 120 VAC
Circulator Relay: 14.5 FLA–25.0 LRA @ 120 VAC
Flame Current Requirements:
Min current to insure flame detection: 1 μa DC*
Max current for non-detection: 0.1 μa DC*
Max allowable leakage resistance: 100 M ohms
*Measured with a DC microammeter in series with the flame
probe lead
OPERATING TEMPERATURE RANGE:
-40° to 176°F (-40° to 80°C)
HUMIDITY RANGE:
5% to 93% relative humidity (non-condensing)
MOUNTING:
Surface mount multipoise
TIMING SPECS: (@ 60 Hz)
Flame Establishing Time:
Flame Failure Response Time:
GASES APPROVED: Natural, Manufactured, Mixed, Liquid
Petroleum, and LP Gas Air Mixtures are all approved for use.
maximum
0.8 sec
2.0 sec
emerson.com/white-rodgers
50M56-820
Integrated Single Stage
Hot Surface Ignition Control
INSTALLATION INSTRUCTIONS
Parts included:
50M56-820 Integrated Furnace Control
789A-820 Ignitor Kit (120V HSI Ignitor,
Mounting Bracket, 3 Screws)
Ignitor Adapter Harness for Older 80V HSI Units
Cover
4 Standoffs
4 Screws
2 Wire Ties
Installation Instructions
4 Wiring Extensions
CAUTION
!
Risk of Electric Shock.
Disconnect electric power
to system until installation
is complete. Do not use
on circuit exceeding
specified voltage. Higher
voltage will damage the
module and could cause
shock or fire hazard.
Not intended for use in
locations where it may
come in contact with
water.
May cause flame rollout.
Shut off main gas to
heating
installation is complete.
DESCRIPTION
SPECIFICATIONS
system
until
PART NO. 37-7808001
2004

Publicité

Table des Matières
loading

Sommaire des Matières pour Emerson White-Rodgers 50M56-820

  • Page 1 Surface mount multipoise TIMING SPECS: (@ 60 Hz) maximum Flame Establishing Time: 0.8 sec Flame Failure Response Time: 2.0 sec GASES APPROVED: Natural, Manufactured, Mixed, Liquid Petroleum, and LP Gas Air Mixtures are all approved for use. PART NO. 37-7808001 emerson.com/white-rodgers 2004...
  • Page 2: Wiring Diagram

    WIRING DIAGRAM Neutral 120 VAC HUM (120V) 24 VAC TR 24 VAC CLASS II (120V) TRANSFORMER (LINE) Inducer Unused Motor NEUTRAL (LINE) Heat Blower Motor Cool Ignitor Dipswitch Fault COOL “OFF” DELAY Code Twinning HEAT “OFF” DELAY Retrieval Terminal Flame Sensor Fuse High...
  • Page 3: Mounting Options

    INSTALLATION MOUNTING AND WIRING 3. Mount the new control board in the unit and reconnect all the wires. Secure any wiring as necessary. NOTE: All wiring should be installed according to local and 4. Reinstall unit access panels and reconnect electric power national electrical codes and ordinances.
  • Page 4: Configuration

    CONFIGURATION DIPSWITCHES The dipswitch on the 50M56 control is used to determine the length of the heat delay-to-fan-off period and cool delay-to-fan- COOL OFF off period. The following table shows the time periods that will result from the various switch positions. HEAT OFF COOL "OFF"...
  • Page 5: Cool Mode

    OPERATION COOL MODE Output Cooling until Thermostat is Satisfied 2 sec 0*/80 sec Thermostat Outdoor Compressor Outdoor Fan Blower (Cooling Speed) * Default FAN MODE Output Fan until Thermostat is Satisfied Thermostat - G Blower (Fan Speed)
  • Page 6 TROUBLESHOOTING FAULT RECALL Red LED When the control is in Standby mode (no call for heat or cool), Flash Status/Error Condition press the fault recall switch for approximately 2 seconds or until System Lockout (Retries or Recycles the diagnostic LED turns off. Up to 5 fault codes are stored. Exceeded) NOTE: While displaying the stored fault codes, the control will ignore any new call for heat, cool or fan.
  • Page 7 NOTES...
  • Page 8 TECHNICAL SUPPORT: 1-888-725-9797 Emerson and White-Rodgers are trademarks of Emerson Electric Co. ©2020 Emerson Electric Co. emerson.com/white-rodgers All rights reserved.
  • Page 9: Spécifications

    GAZ APPROUVÉS : Le gaz naturel, le gaz manufacturé, le gaz chauffage jusqu’à mélangé, les gaz de pétrole liquéfiés et les mélanges de gaz de ce que l’installation soit pétrole liquéfiés et d’air sont tous approuvés. terminée. DE PIÈCE 37-7808001 emerson.com/white-rodgers 2004...
  • Page 10: Schéma De Câblage

    SCHÉMA DE CÂBLAGE Neutre 120 V c.a. HUM (120 V) 24 V c.a. TR TRANSFORMATEUR (120 V) 24 V C.A. CLASSE II SOUS TENSION (SECTEUR) Moteur de Non utilisé l’inducteur NEUTRE (LIGNE) Moteur du Chauffage souffleur Climatisation Allumeur Commutateur DIP Récupération DÉLAI ARRÊT CLIM du code de...
  • Page 11: Montage Et Câblage

    INSTALLATION MONTAGE ET CÂBLAGE 3. Montez le nouvelle tableau de commande dans l’appareil et rebranchez tous les fils. Sécurisez le câblage si nécessaire. REMARQUE : Tout le câblage doit être installé conformément aux 4. Réinstallez les panneaux d’accès de l’appareil et reconnectez codes et ordonnances locaux et nationaux de l’électricité.
  • Page 12: Commutateurs Dip

    CONFIGURATION COMMUTATEURS DIP Les commutateurs DIP de la commande 50M56 sont utilisés pour déterminer la durée du délai de chauffage-au-ventilateur-à-l’arrêt et ARRÊT CLIM du délai de climatisation-au-ventilateur-à-l’arrêt. Le tableau suivant montre les durées qui correspondent aux différentes positions du commutateur. ARRÊT CHAUF DÉLAI ARRÊT CLIM DÉLAI ARRÊT CHAUF...
  • Page 13: Mode Climatisation

    FONCTIONNEMENT MODE CLIMATISATION Climatisation jusqu’au réglage du Sortie thermostat 0*/80 s Thermostat Compresseur extérieur Ventilateur extérieur Souffleur (vitesse de climatisation) * Défaut MODE VENTILATEUR Sortie Ventilateur jusqu’au réglage du thermostat Thermostat – G Souffleur (vitesse du ventilateur)
  • Page 14: Dépannage

    DÉPANNAGE RAPPEL D’ALERTE DEL rouge Lorsque la commande est en mode attente (aucune commande clignotante Statut / Erreur de chauffage ni de climatisation), enfoncez le bouton de rappel Neutralisation du système (excède le d’erreur (Fault Recall) pendant environ 2 à 5 secondes ou jusqu’à nombre d’essais ou de cycles permis) ce que la DEL de diagnostic s’éteigne.
  • Page 15: Remarques

    REMARQUES...
  • Page 16 SOUTIEN TECHNIQUE : 1-888-725-9797 Emerson et White-Rodgers sont des marques de commerce d’Emerson Electric Co. ©2020 Emerson Electric Co. emerson.com/white-rodgers Tous droits réservés.

Table des Matières